My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1988-2004
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
950
>
2300 - Underground Storage Tank Program
>
PR0231401
>
COMPLIANCE INFO_1988-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:32 AM
Creation date
6/3/2020 9:48:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1988-2004
RECORD_ID
PR0231401
PE
2361
FACILITY_ID
FA0006388
FACILITY_NAME
KWIK SERVE
STREET_NUMBER
950
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23406002
CURRENT_STATUS
01
SITE_LOCATION
950 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231401_950 W ELEVENTH_1988-2004.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
566
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
k. t: ,.. ;.;- �,r'^%'""2"P?"�"" ._.:*�.;.-. ;.-.a.:.-�-�Fg..a:hr1�'r�"'".y�. .-.v.�-v,.v,-�.,.c+e,.,�,.f�.-yr-.,•--T..,"-a-K—w.-, "-..R"m.�,;..,,y.,.....- . � <br /> STATE OF CALIFORNI WATER RESOURCES CONTRA <br /> RD <br /> FORM `B'• UNDEP <br /> ROUND <br /> OUN STORAGE TANK PRQ RAM " <br /> TANK A, TANK PERMIT APPLICATION INFORMATIONO <br /> - <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. C4llF0 N.P <br /> MARK ONLY ❑ 1 NEW PERMIT ❑3 RENEWAL PERMIT ❑5 CHANGE OF INFORMATION ❑7 PERMANENTLY CLOSED TANK <br /> ONE ITEM ❑2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: � FARM TANK-YES❑ NO <br /> 1. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY <br /> A. OWNERS TANK ID# h ¢� B. MANUFACTURED BY: <br /> C. YEAR INSTALLED l D. TANK CAPACITY IN GALLONS: 10, <br /> W <br /> 11. TANK C TENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. t Ln <br /> A• 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. E] 1 UNLEADED LEADED -] 3 DIESEL <br /> ❑3 CHEMICAL PRODUCT ❑ 4 OIL 1 PRODUCT ❑ 4 GASAHOL ❑5 JET FUEL ❑6 AVIATION GAS <br /> ❑5 HAZARDOUS ❑ 80 EMPTY ❑95 UNKNOWN ❑ 2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# C.A.S.#: / <br /> x111. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> di <br /> A.TYPE OF DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM ❑2 SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑99 OTHER <br /> ❑1 STEEL/IRON ❑2 STAINLESS STEEL FIBERGLASS ❑4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK <br /> MATERIAL ❑5 CONCRETE F-16 POLYVINYL CHLORIDE F-17 ALUMINUM ❑8 100%METHANOL COMPATIBLE FRP <br /> ❑9 BRONZE ❑ 10 GALVANIZED STEEL ❑95 UNKNOWN ❑99 OTHER <br /> C. INTERIOR ❑ 1 RUBBER LINED El2 ALKYD LINING F-13 EPDXY LINING ❑4 PHENOLIC LINING <br /> LINING ❑5 GLASS LINING ❑6 UNLINED ❑95 UNKNOWN <br /> ❑IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑NO ❑99 OTHER <br /> D.CORROSION ❑1 POLYETHLENE WRAP ❑2 TAR OR ASPHALT ❑3 VINYL WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑91 NONE ❑95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A.SYSTEM TYPE A U i SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 99 OTHER <br /> B.CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A LINED TRENCH A U 95 UN WN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A 4 FIBERGLASS PIPE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S 1 VISUAL CHECK P S 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS PS 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> E('L/ GALLONS SUBSTANCE REMAINING IN INERT MATERIAL? ❑YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANTS NAME(PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> AGI 1:1Loio-1 / o-71 Eo I o 0 5' <br /> CURRENT LOCAL AGENCY FACILITY ID# APPROVED BY NAME PHONE#WITH AREA CODE <br /> PERMIT NUMBER PERMIT APPROVAL DATE TERMIT EXPIRATION DATE <br /> CHECK# PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT# BY: <br /> FORM B(3-7-88) THIS FORM MUST BE ACCOMPANIE of A FACILITY/SITE APPLICATION, FORM`A',UNLESS A - RENT FORM`A' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.