Laserfiche WebLink
. � DATE 2 <br /> SAN JOAQUIN COUNTY PR# <br /> ENVIRONMENTAL HEALTH DEPARTMENT PAGE 2, <br /> 304 E.Weber Ave.,Third Floor, Stockton, CA 95202 <br /> (209)468-3420 <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> Facility Name d °N �'DDS �' ue.Q__Facility Address 3'f2-5 N • - v-LA. c s. E%ri4 `�tira.c.H <br /> Facilty Contact CRY 01I ht Qe.400 Title Phone # ZOa , g36 • 1(a06 <br /> UST# U Productl=cn �L UST#_1Product UST#_JProduc r UST#Prod l _ <br /> Overfill Prevention: [IAudibleNisual C!ilechanical Monitoring Panel: RDn0,' Liu <br /> Piping System: ❑ Gravity C�,Pressure ❑Suction � Violations: "inor ❑ Major <br /> Automatic Pump Shut Down Satisfies CCR 2636(g): ❑Yes <br /> VNo Dispenser Pan: ❑Yes iso rav' <br /> INSPECTION TYPE: gRoutine FlMonitoring Certification ❑Complaint ❑Install ❑Removal ❑Repair/Upgrade <br /> COMPANY NAME: TECHNICIAN NAME: CYou PHONE:7J Lf. 5U0 . <br /> VIOLATION(S) <br /> The above facility is not in compliance with the following section(s) of Health & Safety Code (HSC) and/or <br /> California Code of Regulations (CCR):: <br /> 1 HSC 25284 Permit to operate 20 CCR 2712 (b) Maintenance & monitoring <br /> 2 CCR 2637 Secondary cont testing (6 records <br /> month/36 month) 21 CCR 2636 (f)(4) Annual line tightness test <br /> 3 -CCR 2711(b) & (c) Current State Forms A& B 22__�;7CCR 2630 (d) Annual line leak detector test <br /> ( ) <br /> 4 -HSC 25292.2 Certification of financial 23 d 2630 CCR Annual monitoring certification <br /> � <br /> responsibility and letter from 24 CCR 2643 (d) Daily monitoring of suction <br /> chief financial officer piping that is not continuously <br /> 5 CCR 2630 (d) Continuous monitoring system monitored <br /> for UST system 25 CCR 2636 (a) Conventional suction piping <br /> 6 CCR 2636 (c)(1) All releases in secondary piping shall have continuous <br /> flow to a collection sump monitoring &20 containment <br /> 7 HSC 25291 (e) Water in secondary(20)cont 26 CCR 2643 (e) Biennial <br /> P ng that st not continuouslyhtness test ofgrt} <br /> 8 HSC 25291 (f) Automatic line leak detector(s) monitored <br /> 9 CCR 2636 (f)(1) Continuous monitoring system <br /> for underground piping 27 CCR 2662 Upgrade requirements for UST <br /> 10 CCR 2632 (c)(2) Continuous monitoring system system <br /> for UST 28 CCR 2661 Permit to repair UST system <br /> 11 HSC 25291(a)(2) Secondary containment for 29 HSC 25286 (a) Permit to alter monitoring <br /> UST is tight system <br /> 12 CCR 2636 (f)(1) Continuous monitoring system 30 HSC 25298 (a) Illegal abandonment of UST <br /> for dispenser system <br /> ystem <br /> 13 CCR 2635 (b)(1) Spill container 31 HSC 25298 (b) Permit to temporarily close US" <br /> 14 CCR 2635 (b)(2) Overfill prevention system system <br /> 15 CCR 2631 (a) Primary containment is product- 32 HSC 25298 (c) Permit to close UST system <br /> tight 33 HSC 25291 (e) Water in 20 cont analyzed and <br /> 16 HSC 25292.1 UST system is operated to properly disposed of <br /> prevent unauthorized release 34 CCR 2640 (e) Single wall component within <br /> 17 CCR 2650 Recording/reporting 1000'of Public Well, no ELD <br /> unauthorized release 35 CCR 2635(a)(2)(A)Cathodic protection testing <br /> 18 CCR 2632 (d) Monitoring &response plan 36 H&SC 25299(a)(9)Disabling leak detect. devices <br /> 19 CCR 2712 (i) Monitoring &response plan is 37 Violation(s) not listed above <br /> on site <br /> EHD INSPECTOR:Vt (,IiYt A, PHONE: <br /> RECEIVED BY: TITLE: <br /> UNITIII/USTANSP(rev 7/24/02) <br />