lyiitoring System Certification Is <br /> Site Address 3425 TRACY BLVD Date of Testing/Service: 12/29/2009 <br /> D. Results of Testing/Servicing <br /> Software Version Installed: 328.03 <br /> Complete the following checklist: <br /> X Yes No Is the audible alarm operational? <br /> El Yes No Is the visual alarm operational? <br /> Q Yes No Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not <br /> Q Yes ❑No interfere with their proper operation? <br /> Yes No. x N/A If alarms are relayed to a remote monitoring station,is all communications equipment(e.g. modem)operational? <br /> For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment <br /> Q Yes ❑No ❑N/A monitoring system detects a leak,fails to operate,or is electrically disconnected?If yes:which sensors initiate positive <br /> shut-down?(check all that apply) ❑X Sump/Trench Sensors; ❑x Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks aad sensor failure/disconnection? ❑x Yes No <br /> ❑x Yes ❑No N/A For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.:no mechanical <br /> overfill prevention valve is installed),is the overfill warning alarm visible and audible at the tank fill points(s)and operating <br /> properly? If so,at what percent of tank capacity does the alarm trigger? 90 /o <br /> ❑ Yes* ❑x No Was any monitoring equipment replaced?If yes,identify specific sensors,probes,or other equipment replaced and list the <br /> manufacturer name and model for all replacement parts in Section E,below. <br /> a Yes' ®No Was liquid found inside any secondary containment systems designed as dry systems?(check all that apply) ❑Product; <br /> ❑x Water. If yes,describe causes in Section E,below. <br /> ❑x Yes ❑No Was monitoring system set-up reviewed to ensure proper settings?Attach set-up reports,if applicable. <br /> ❑ Yes 0 No` Is all monitoring equipment operational per manufacturers'specifications? <br /> *In Section E below,describe how and when these deficiences were or will be corrected. <br /> E. Comments: <br /> BOTH 87,AND 91 LEAK DETECTORS FAILED.. DUE TO SYPHON JET VALVES.COULD NOT REMOVED PLUGS ON 871AUXILIAR7,_OTF9T_ <br /> I URBINES I U KtIlLAUt 6Yk1HUN JE I VALVES.(WA6 ABLE 10 REPLACE 81/MAIN SYPHUN JE I VALVE�j GALL <br /> AND DISPOSED 15F HAZARDOUS WASTE DRUM. <br /> Page 2 of 3 Based on CA form dated 03/08 <br />