COMPLIANCE INFO_2009-2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3425
>
2300 - Underground Storage Tank Program
>
PR0231416
>
COMPLIANCE INFO_2009-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2024 3:53:46 PM
Creation date
6/3/2020 9:48:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2011
RECORD_ID
PR0231416
PE
2361
FACILITY_ID
FA0003627
FACILITY_NAME
ARCO 02093
STREET_NUMBER
3425
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21418020
CURRENT_STATUS
01
SITE_LOCATION
3425 TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231416_3425 TRACY_2009-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
320
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br /> INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br /> .fr MW*rxiogy <br /> TEST DATE:01/07/10 8501 N MOPAC EXPRESSWAY,SUITE 400 WORK ORDER NUMBER2271462 <br /> CLIENT:BP PRODUCTS NORTH AUSTIN,TEXAS 78759(512)451-6334 SITE:ARCO # 02093 CC18022760 <br /> 2121=222M <br /> Tank ID: MAIN 2 Tank manifolded: YES Bottom to top fill in inches: 96.0 <br /> Product: UNLEADED Vent manifolded: YES Bottom to grade in inches: <br /> Capacity in gallons: 9,684 Vapor recovery manifolded: YES Fill pipe length in inches: <br /> Diameter in inches: 96.00 Overfill protection: YES Fill pipe diameter in inches: <br /> Length in inches: 313 Overspill protection: YES Stage I vapor recovery: DUAL <br /> Material: DW FIBERG Installed: ATG Stage 11 vapor recovery: ASSIST <br /> CP installed on: <br /> COMMENTS <br /> Start(in) End(in) <br /> Dipped Water Level: New/passed Failed/replaced New/passed Failed/replaced <br /> Dipped Product Level: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> Probe Water Level: Make: VEEDERROOT <br /> Ingress Detected: Water Bubble Ullage Model: ELECTRONIC <br /> Test time: S/N: <br /> Inclinometer reading: Open time in sec: <br /> VacuTect Test Type: NOT Holding psi: 19 <br /> VacuTect Probe Entry Point: TESTED Resiliency cc: NOT <br /> Pressure Set Point: Test leak rate ml/m: 189.0 TESTED <br /> Tank water level in inches: Metering psi: <br /> Water table depth in inches: Calib. leak in gph: 3.00 <br /> Determined by(method): Results: PASS <br /> Result: <br /> COMMENTS <LICOMMENTS <br /> ME OF-,j 177. <br /> TTq <br /> Material: DW FIBERG <br /> Diameter(in): <br /> Length(ft): <br /> Test psi: <br /> Bleedback cc: <br /> Test time(min): NOT NOT NOT NOT <br /> Start time: TESTED TESTED TESTED TESTED <br /> End time: <br /> Final gph: <br /> Result: <br /> Pump type: PRESSURE <br /> Pump make: FE PETRO <br /> COMMENTS Impact Valves Operational: YES <br /> Printed 01/13/2010 14:19 <br />