Laserfiche WebLink
Page_ of <br /> S. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sums [I _ <br /> Pill Riser Containment Sums are Present>but were Not Tested 0 <br /> Test Method Developed By: ❑Sump Manufacturer N Industry Standard ❑Professional Engineer <br /> 0 Other(Specify) <br /> Test Method Used: O Pressure E] Vacuum ®Hydrostatic <br /> D Other(Specify) <br /> Test Equipment Used: Wayne Perry Inc.See Attached Results Equipment ResoIution:•0007" <br /> Sump# T 7 Sump# 17- 7-- Sump# 9-.3 Sump# /pry/ <br /> >f f T 5 >9 <br /> Sump Diameter: <br /> Sump Depth: d 4s'>, :;-7 <br /> Sump Material: <br /> v <br /> Height from Tank Top to Top of >, /� .ri��g " 41.14 " <br /> Highest Piping Penetration: / -.._—_ <br /> Height from Tank Top to Lowest " <br /> 31Electrical Penetration: <br /> Condition of sump prior to testing: v � <br /> Portion of Sump Tested' 2"ABOVE HIGHEST 2"ABOVE HIGHEST 2"ABOVE HIGHEST 2"ABOVE HIGHEST <br /> _ PENETRATION PENETRATION PENETRATION PENETRATION <br /> Wait time between applying water 15 Minutes 15 Minutes 15 Minutes 15 Minutes <br /> and starting test: <br /> Test Start Time: 10; :07 //:vG Se53 y•'10 <br /> Initial Reading(R,): ) 5&` r G2. y26 516. c'C <br /> Test End Time: 14), 56 : <br /> Final Reading(Rr): — 7 126 S. ?l 4, 9,21-T-5- E. <br /> Test Duration: 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min. 15 Min 15 Min <br /> Change in Reading(RF-R): oet,� <br /> Pass/Fail Threshold or Criteria: -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020--- <br /> Is <br /> 0.0020Is there a sensor in the sump? 0-yes []No ❑NA [ayes ❑No ®NA E3 Yes 0 No ®NA O-Yes ®No D NA <br /> Does sensor alarm when either ©._Yes L7 No ❑NA [J'Yes D No E1 NA D-Yes E]No D NA ET Yes O No ❑NA <br /> product or water is detected? <br /> Was sensor removed for Testing? C#Yes D No D NA O-Yes Cl No D NA O-Yes O No 0 NA D Yes D No D NA <br /> Was sensor properly replaced and O-Yes D No E]NA [T-Yes D No D NA ( Yes D No [I NA [Q Yes 0 No D NA <br /> verified functional after testing? �� <br /> Comments—(include information on repairs made prior to testing and recommended follow-up for failed tests) <br /> Arco#02093 <br /> 3425 Tracy Blvd„ <br /> Trac,yl Ca 95376 <br /> Nick I arvey <br /> #0914.3 SB 989 <br />