Laserfiche WebLink
EVR., ISD SETUP <br /> RECONCILIATION SETUP EVR TYPE: VACUUM ASSIST <br /> - - - - - - - - - - - - VACUUM ASSIST TYPE <br /> HEAL' VAC <br /> EDIM I G <br /> NOZZLE A,,L RANGE <br /> AUTOMATIC DAILY CLOSING MA".': I . 15 11 IN: 0.95 <br /> TIME: 2:00 AM <br /> VAPOR PROCESSOR TYPE <br /> PLLD LINE DISABLE SETUP AUTO SHIFT 41 CLOSING NONE <br /> - - - - - - - - - - - - TIME: DISABLED <br /> G 1 :87 UNL. REG. AUTO SHIFT #2 CLOSING ANALYSIS TIMES <br /> TIME: DISABLED TIME: 11 :59 PM <br /> IN-TANK ALARMS DELAY MINUTES: I <br /> T I :HIGH WATER ALARM AUTO SHIFT #3 CLOSING <br /> T I :LOW PRODUCT ALARM TIME: DISABLED ACCEPT HIGH ORVR: <br /> LIQUID SENSOR ALMS AUTO SHIFT #4 CLOSING DISABLED <br /> ALL:FUEL ALARM TIME: 6:00 AM <br /> ALL:SENSOR OUT ALARM ISD HOSE TABLE <br /> ALL:SHORT ALARM ID FP FL HL AA RR <br /> PERIODIC RECONCILIATION --___.-- <br /> PRESSURE <br /> _-_--PRESSURE LINE LEAK 11ODE: MONTHLY 01 01 01 02 01 UU <br /> 0 I :PLLD OPEN ALARM ALARM: DISABLED 02 02 02 02 01 UU <br /> 03 03 03 02 02 UU <br /> ISD SITE ALARMS TEMP COMPENSATION 04 04 04 02 02 UU <br /> ISD GROSS PRES FAIL STANDARD 05 05 05 02 03 UU <br /> ISD DEGRD PRES FAIL METER CALIBRATION 06 06 06 02 03 UU <br /> ISD VAPOR LEAK FAIL OFFSET: 0.000% 07 07 07 02 04 UU <br /> ISD VP PRES FAIL 08 08 Oe 02 04 UU <br /> ISD VP STATUS FAIL BUS SLOT FUEL METER TANK <br /> ISD SETUP FAIL - - - - - - - - - - - - <br /> I SD <br /> ISD SENSOR OUT FAIL TANK MAP EMPTY ISD AIRFLOW METER MAP <br /> ID SERIAL NUM LABEL <br /> ISD HOSE ALARMS ------------------------- <br /> ALL:GROSS COLLECT FAIL 1 27724 DISP. 1-2 <br /> ALL:DEGRD COLLECT FAIL 2 27703 DISP. 3-4 <br /> ALL:FLOW COLLECT FAIL <br /> 3 27730 DISP. 5-6 <br /> 4 27738 DISP. 7-8 <br /> Q 2:91 PREMIUM <br /> IN-TANK ALARMS ISD FUEL GRADE HOSE MAP <br /> T 4:HIGH WATER ALARM 1 2 3 4 <br /> T 4:LOW PRODUCT ALARM FP MHH MHH MHH MHH AA <br /> SMARTSENSOR SETUP ------------------------ <br /> LIQUID SENSOR ALMS - - - - - - - - - - - - 01 101 901 301 U U I <br /> ALL:FUEL ALARM 02 102 902 302 U U I <br /> ALL:SENSOR OUT ALARM 3 l :DISP. 1-2 03 103 903 303 U U 2 <br /> ALL:SHORT ALARM CATEGORY AIR FLOW METER 04 104 904 304 U U 2 <br /> 05 105 905 305 U U 3 <br /> ISD SITE ALARMS 2:DISP. 3-4 06 106 906 306 U U 3 <br /> ISD GROSS PRES FAIL CATEGORY AIR FLOW METER 07 107 907 307 U U 4 <br /> ISD DEGRD PRES FAIL 08 108 908 308 U U 4 <br /> ISD VAPOR LEAK FAIL 3:DISP. 5-6 <br /> ISD VP PRES FAIL CATEGORY AIR FLOW METER <br /> ISD VP STATUS FAIL LABEL TABLE <br /> ISD SETUP FAIL 4:DISP. 7-8 ------------------------ <br /> ISD SENSOR OUT FAIL CATEGORY AIR FLOW METER 1 : UNASSIGNED <br /> 2: BLEND3 <br /> ISD HOSE ALARMS 5:PRESSURE SENSOR 3-4 3: REGULAR <br /> ALL:GROSS COLLECT FAIL CATEGORY VAPOR PRESSURE 4: MID GRADE <br /> ALL:DEGRD COLLECT FAIL 5: PREMIUM <br /> ALL:FLOW COLLECT FAIL 6: GOLD <br /> 7: BRONZE <br /> 8: SILVER <br /> 9: BLEND2 <br /> 10: BLEND4 <br />