TRACY
>
3425
>
2300 - Underground Storage Tank Program
>
PR0231416
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2024 4:04:04 PM
Creation date
6/3/2020 9:48:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231416
PE
2361
FACILITY_ID
FA0003627
FACILITY_NAME
ARCO 02093
STREET_NUMBER
3425
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21418020
CURRENT_STATUS
01
SITE_LOCATION
3425 TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231416_3425 TRACY_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
599
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 <br />4. TANK ANNULAR TESTING <br />Page _3 of _9_ <br />Test Method Developed By: ❑ Tank Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ® Vacuum ❑ Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: 0 — 30" VACUUM GAUGES Equipment Resolution: .5% <br />Is Tank Exempt From Testing?' <br />Tank Capacity: <br />Tank Material: <br />Tank Manufacturer: <br />Product Stored: <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />Test Start Time: <br />Initial Reading (Rj): <br />Test End Time: <br />Final Reading (RF): <br />Test Duration: <br />Change in Reading (RF -R,): <br />Pass/Fail Threshold or Criteria: <br />Test Result: <br />Was sensor removed for testing? <br />Was sensor properly replaced and <br />verified functional after testing? <br />Tank # 87(1) <br />❑ Yes ® No <br />10000 <br />FIBERGLASS <br />XERXES <br />87 <br />RIIET, 1 <br />8:30 <br />10" <br />9:30 <br />10" <br />1 HR <br />0 <br />NO LOSS <br />0 Pass ❑ Fail;. " <br />Eyes ❑ No [:INA <br />®Yes ❑No [-INA <br />Tank # 87(2) <br />❑ Yes ® No <br />10000 <br />FIBERGLASS <br />XERXES <br />87 <br />10 MIN <br />8:30 <br />10" <br />9:30 <br />10" <br />1 HR <br />0 <br />NO LOSS <br />Eyes [:]No ❑ NA <br />® Yes ❑ No ❑ NA <br />Tank # 87(3) <br />❑ Yes ® No <br />10000 <br />FIBERGLASS <br />XERXES <br />87 <br />10 MIN <br />8:30 <br />10" <br />9:30 <br />10" <br />1 HR <br />0 <br />NO LOSS <br />®Yes [:]No [-INA <br />®Yes ❑No [-]NA <br />Tank # 91 <br />❑ Yes ® No <br />10000 <br />FIBERGLASS <br />XERXES <br />91 <br />10 MIN <br />8:30 <br />10" <br />9:30 <br />10" <br />1 HR <br />0 <br />NO LOSS <br />®Yes E] No ❑NA <br />Eyes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />� � J <br />"NVIRONMENTAF <br />1 Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. {California Code of Regulations, Title 23, Section 2637(a)(6)) <br />