My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3425
>
2300 - Underground Storage Tank Program
>
PR0231416
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2024 4:04:04 PM
Creation date
6/3/2020 9:48:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231416
PE
2361
FACILITY_ID
FA0003627
FACILITY_NAME
ARCO 02093
STREET_NUMBER
3425
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21418020
CURRENT_STATUS
01
SITE_LOCATION
3425 TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231416_3425 TRACY_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
599
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ALL ELIVY DENSITY WARN <br />LIQUID SENSOR ALMS <br />ALL:FUEL ALARM <br />ALL:SENSOR OUT ALARM <br />ALL:SHORT ALARM <br />ALL:WATER ALARM <br />ALL:WATER OUT ALARM <br />ALL:HIGH LIQUID ALARM <br />ALL:LOW LIQUID ALARM <br />ALL.:LIQUID WARNING <br />COMM SIDE DIM ALPS <br />ALL:DISABLED DIM ALARM <br />ALL:COMMUNICATION ALARM <br />ALL:TRANSACTION ALARM <br />RECONCILIATION ALM <br />ALL:PROD THRESHOLD ALM <br />ALL:CLOSE SHIFT WARNING <br />ALL:CLOSE DAILY WARNING <br />PRESSURE LINE LEAK <br />ALL:GROSS LINE FAIL <br />ALL:ANNUAL LINE FAIL <br />ALL:PER TST NEEDED WRN <br />ALL:PER TST NEEDED ALM <br />ALL:PLLD OPEN ALARM <br />ALL:UNKNOWN ALARM <br />ALL:PLLD SHUTDOWN ALARM <br />ALL:UNKNOWN ALARM <br />ALL:UNKNOWN ALARM <br />ALL:PERIODIC LINE FAIL <br />ALL:ANN TST NEEDED WRN <br />ALL:ANN TST NEEDED ALM <br />ALL:LOW PRESSURE ALARM <br />ALL:UNKNOWN ALARM <br />ALL:CONT HANDLE ALM <br />ALL:FUEL OUT <br />ALL:LN EQUIP FAULT ALPS <br />SMARTSENSOR ALARMS <br />ALL:SETUP DATA WARNING <br />ALL:COMMUNICATION ALARM <br />ALL:SENSOR FAULT ALARM <br />ALL:FUEL WARNING <br />ALL:FUEL ALARM <br />ALL:WATER WARNING <br />ALL:WATER ALARM <br />ALL:HIGH LIQUID WARNING <br />ALL:HIGH LIQUID ALARM <br />ALL:LOW LIQUID WARNING <br />ALL:L0W LIQUID ALARM <br />ALL:TEMPERATURE WARNING <br />ALL:RELAY ACTIVE <br />ALL:INSTALL ALARM <br />ALL:SENSOR FAULT WARN <br />ALL:VACUUM WARNING <br />ALL:NO VACUUM ALARM <br />ISD SITE ALARMS <br />ISD STAGE I WARN <br />ISD GROSS PRES WARN <br />ISD GROSS PRES FAIL <br />ISD DEGRD PRES WARN <br />ISD DEGRD PRES FAIL <br />ISD VAPOR LEAK WARN <br />ISD VAPOR LEAK FAIL <br />ISD VP PRES WARN <br />ISD VP PRES FAIL <br />ISD VP STATUS WARN <br />ISD VP STATUS FAIL <br />MISSING RELAY SETUP <br />MISSING HOSE SETUP <br />(°MISSING TANK SETUP <br />MISS VAPOR FLOW MTR <br />(°MISS VAPOR PRES SEN <br />MISSING VP INPUT <br />ISD SETUP WARN <br />ISD SETUP FAIL <br />ISD SENSOR OUT WARN <br />ISD SENSOR OUT FAIL <br />PC -ISD FAILURE <br />'D HOSE ALARMS <br />ALL:GROSS COLLECT WARN <br />ALL:GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT WARN <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT WARN <br />ALL:FLOW COLLECT FAIL <br />ALL:AIRFLOW MTR SETUP <br />VAPOR FLW MTR ALMS <br />ALL:CHK VAPOR FL0W MTR <br />PMC ALARMS <br />VP RUNTIME FAULT <br />VP EMISSIONS WARN <br />VP EMISSIONS FAIL <br />VP PRESSURE WARN <br />VP PRESSURE FAIL <br />VP DUTY CYCLE WARP! <br />VP DUTY CYCLE FAIL <br />PMC SETUP FAIL <br />IPJ -TANK SETUP <br />T 1 :UNLEADED R 6-7 & IccvU <br />PRODUCT CODE <br />I <br />THERMAL COEFF <br />:.000700 <br />TANK DIAMETER <br />96.00 <br />TANK PROFILE <br />4 PTS <br />FULL VOL <br />9684 <br />72.0 INCH VOL <br />: 8411 <br />48.0 INCH VOL <br />5354 <br />24.0 INCH VOL <br />: 2094 <br />("METER DATA <br />: NO <br />FLOAT SIZE: 2.0 IN. <br />WATER WARNING 2.0 <br />HIGH WATER LIMIT: 3.0 <br />WATER ALARM FILTER: L0W <br />MAX OR LABEL VOL: 9684 <br />OVERFILL LIMIT 90% <br />8715 <br />HIGH PRODUCT 95% <br />9199 <br />DELIVERY LIMIT 10% <br />968 <br />tVNUAL TEST FAIL <br />ALARM DISABLED <br />PERIODIC TEST FAIL <br />ALARM DISABLED <br />GROSS TEST FAIL <br />ALARM DISABLED <br />ANN TEST AVERAGING: OFF <br />PER TEST AVERAGING: OFF <br />TANK TEST NOTIFY: OFF <br />TNK tST SIPHON BREAK :OFF <br />DELIVERY DELAY 3 M I N <br />PUMP THRESHOLD 10.00`a <br />T 2: UNLEADED R S'1 MasVZ'Y' <br />PRODUCT CODE I <br />THERMAL COEFF :.000700 <br />TANK DIAMETER <br />96.00 <br />TANK PROFILE <br />4 PTS <br />FULL VOL <br />9684 <br />72.0 INCH VOL <br />8411 <br />48.0 INCH VOL <br />5341 <br />24.0 INCH VOL <br />2094 <br />METER DATA <br />: NO <br />FLOAT SIZE: <br />2.0 IN. <br />WATER WARNING 2.0 <br />HIGH WATER LIMIT: 3.0 <br />WATER ALARM FILTER: LOW <br />MAX OR LABEL VOL: 9684 <br />OVERFILL LIMIT 900% <br />8715 <br />HIGH PRODUCT 95% <br />9199 <br />DELIVERY LIMIT 10a <br />968 <br />LOW PRODUCT 511 <br />LEAK ALARM LIMIT: 99 <br />SUDDEN LOSS LIMIT: 99 <br />TANK TILT 0.00 <br />PROBE OFFSET 0.00 <br />SIPHON MANIFOLDED TANKS <br />LOW PRODUCT 511 T#: 01,03 <br />LEAK ALARM LIMIT: 99 LINE MANIFOLDED TANKS <br />SUDDEN LOSS LIMIT: 99 T#: 01.03 <br />TANK TILT 0.00 <br />PROBE OFFSET 0.00 <br />LEAK MIN PERIODIC: 0% <br />0 <br />SIPHON MANIFOLDED TANKS <br />T#: 02,03 LEAK MIN ANNUAL Ori <br />LINE MANIFOLDED TANKS 0 <br />T#: 02,03 <br />PERIODIC TEST TYPE <br />LEAK MIN PERIODIC: 0% STANDARD <br />u <br />ANNUAL TEST FAIL <br />LEAK MIN ANNUAL 0% ALARM DISABLED <br />0 <br />PERIODIC TEST FAIL <br />ALARM DISABLED <br />PERIODIC? TEST TYPE <br />STANDARD <br />
The URL can be used to link to this page
Your browser does not support the video tag.