My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1993-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3725
>
2300 - Underground Storage Tank Program
>
PR0231417
>
COMPLIANCE INFO_1993-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2024 12:44:24 PM
Creation date
6/3/2020 9:48:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1993-2005
RECORD_ID
PR0231417
PE
2361
FACILITY_ID
FA0003780
FACILITY_NAME
TRACY SHELL*
STREET_NUMBER
3725
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21217030
CURRENT_STATUS
01
SITE_LOCATION
3725 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231417_3725 N TRACY_1993-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
412
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br />{ s • . <br />TEST DATE:03/30/99 8900 SHOAL CREEK, BUIL IN200 WORK ORDER NUMBER2208073 <br />CLIENT:EQUIVA SERVICES, LLC AUSTIN, TEXAS 78757 (512) 451-6334 SITE:SHELL 204-7884-0901 <br />Tank ID: 1 Tank manifolded: No Bottom to top fill in inches: <br />Product: PREMIUM Vent manifolded: No Bottom to grade in inches: <br />Capacity in gallons: 11,627 Vapor recovery manifolded: YES Fill pipe length in inches: <br />Diameter in inches: 92.00 Overfill protection: YES Fill pipe diameter in inches: <br />Length in inches: 409 Overspill protection: YES Stage I vapor recovery: <br />Material: DW FIBERG Installed: ATG Stage II vapor recovery: <br />CP installed on: <br />COMMENTS <br />144.0 <br />52.0 <br />4.0 <br />DUAL <br />ASSIST <br />WKWOM <br />40" ` <br />Start (in) <br />End (in) New/passed Failed/replaced New/passed <br />Failed/replaced <br />Dipped Water Level: <br />L.D. #1 L.D. #1 L.D. #2 <br />L.D. #2 <br />Dipped Product Level: <br />Make: VEEDERRooT <br />Probe Water Level: <br />Model: L.L.D. <br />Ingress Detected: water Bubble <br />Ullage S/N: SIMPLICITY-PLLD <br />Test time: <br />Open time in sec: <br />Inclinometer reading: <br />Holding psi: 18 <br />VacuTect Test Type: NOT <br />Resiliency cc: 80 NOT <br />VacuTect Probe Entry Point: TESTED <br />Test leak rate ml/m: 189.0 TESTED <br />Pressure Set Point: <br />Metering psi: 10 <br />Tank water level in inches: <br />Calib. leak in gph: 3.00 <br />Water table depth in inches: <br />Results: PASS <br />Determined by (method): <br />Result: <br />COMMENTS <br />COMMENTS <br />Material: DW FIBERG <br />Impact Valves Operational: UNKNOWN <br />Diameter (in): 2.0 <br />Length (ft): 150.0 <br />COMMENTS <br />Test psi: <br />Bleedback cc: <br />Test time (min): <br />Test 1: Start time: <br />Finish psi: NOT NOT NOT <br />NOT <br />Vol change cc: TESTED TESTED TESTED <br />Test 2: Start time: <br />TESTED <br />Finish psi: <br />Vol change cc: <br />Test 3: Start time: <br />Finish psi: <br />Vol change cc: <br />Final gph: <br />Result: <br />Pump type: PRESSURE <br />Pump make: RED JACKET <br />Printed 05/20/1999 10:47 MSHAW <br />