Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
290
>
2300 - Underground Storage Tank Program
>
PR0231438
>
COMPLIANCE INFO_2003-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2023 2:15:50 PM
Creation date
6/3/2020 9:49:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2015
RECORD_ID
PR0231438
PE
2361
FACILITY_ID
FA0003716
FACILITY_NAME
SUPER STOP GAS & LIQUOR*
STREET_NUMBER
290
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
22309101
CURRENT_STATUS
01
SITE_LOCATION
290 N MAIN ST STE C
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231438_290 N MAIN_2003-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
504
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HUIV, tAlbXNt-AL 114FUl ON TNK TST SIPHON BREAK:OFF <br /> DISABLED T 3:UNLEADED <br /> AUTO EXTERNAL INPUT OFF DELIVERY DELAY 5 MIN - PRODUCT CODE 3 <br /> DISABLED PUMP THRESHOLD 10-00% THERMAL COEFF : .000700 <br /> AUTO SENSOR FUEL ALARM TANK DIAMETER 95.00 <br /> DISABLED TANK PROFILE 4 PTS <br /> AUTO SENSOR WATER ALARM FULL VOL 11400 <br /> DISABLED 71 .3 INCH VOL 9479 <br /> AUTO SENSOR OUT ALARM 47.5 INCH VOL 5892 <br /> DISABLED 23.8 INCH VOL 2304 <br /> FLOAT SIZE: 4.0 IN. <br /> WATER WARNING 2.0 <br /> T 2:DIESEL HIGH WATER LIMIT: 3.0 <br /> PRODUCT CODE 2 MAX OR LABEL VOL: 11400 <br /> RS-232 END OF MESSAGE THERMAL COEFF : .000450 OVERFILL LIMIT 901/0 <br /> DISABLED TANK DIAMETER 95.00 10260 <br /> TANK PROFILE 4 PTS <br /> FULL VOL 6000 HIGH PRODUCT 95% <br /> 10830 <br /> 71 .3 INCH VOL 4690 DELIVERY LIMIT 15% <br /> 47.5 INCH VOL 2915 1710 <br /> 23.8 INCH VOL 1140 <br /> LOW PRODUCT 400 <br /> LEAK ALARM LIMIT: 99 <br /> FLOAT SIZE: 3.0 IN. SUDDEN LOSS LIMIT: 25 <br /> WATER WARNING 2.0 TANK TILT 0.00PROBE OFFSET 0.00 <br /> HIGH WATER LIMIT: 3.0 <br /> IN-TANK SETUP MAX OR LABEL VOL: 6000 <br /> - - - - - OVERFILL LIMIT 90% SIPHON MANIFOLDED TANKS <br /> 5400 T#: NONE <br /> T l :PREMTt(M HIGH PRODUCT 95% LINE MANIFOLDED TANKS <br /> PRODUCT CODE 5700 T#: NONE <br /> THERMAL COEFF : .000700 DELIVERY LIMIT 15,8 <br /> TANK DIAMETER 95.00 900 LEAK MIN PERIODIC: 0% <br /> TANK PROFILE 4 PTS <br /> FULL VOL 5700 LOW PRODUCT 2800 <br /> 71 .3 INCH VOL 4622 LEAK ALARM LIMIT: 99 PERIODIC TEST TYPE <br /> 47.5 INCH VOL 2915 SUDDEN LOSS LIMIT: 25 STANDARD <br /> 23.8 INCH VOL 1140 TANK TILT 0.00 PERIODIC TEST FAIL <br /> PROBE OFFSET 0.00 ALARM DISABLED <br /> FLOAT SIZE: 4.0 IN. SIPHON MANIFOLDED TANKS GROSS TEST FAIL <br /> WATER WARNING 2.0T#: NONE ALARM DISABLED <br /> HIGH WATER LIMIT: 3.0 LINE MANIFOLDED TANKS PER TEST AVERAGING: OFF <br /> MAX OR LABEL VOL: 5700 T#: NONE TANK TEST NOTIFY: OFF <br /> OVERFILL LIMIT 90% <br /> 5130 <br /> LEAK MIN PERIODIC: 0% <br /> HIGH PRODUCT 95% 0 TNK TST SIPHON BREAK:OFF <br /> 5415 DELIVERY DELAY 5 MIN <br /> DELIVERY LIMIT 15% LEAK MIN ANNUAL 0% PUMP THRESHOLD 10.00% <br /> 855 0 <br /> LOW PRODUCT 280 <br /> LEAK ALARM LIMIT: 99 PERIODIC TEST TYPE <br /> SUDDEN LOSS LIMIT: 25 STANDARD <br /> TANK TILT 0.00 <br /> PROBE OFFSET " 0.00 ANNUAL TEST FAIL <br /> ALARM DISABLED <br /> SIPHON HANIFOLDED TANKS PERIODIC TEST FAIL <br /> T#: NONE ALARM DISABLED <br /> LINE MANIFOLDED TANKS <br /> T#: NONE GROSS TEST FAIL LEAK-TEST METHOD <br /> ALARM DISABLED - - - - - - - - - - - <br /> LEAK MIN PERIODIC: 0% ANN TEST AVERAGING: OFF TEST ON DATE : ALL TANK <br /> 0 PER TEST AVERAGING: OFF APR 30, 1999 <br /> PERIODIC TEST TYPE START TIME : DISABLED <br /> STANDARD TANK TEST NOTIFY: OFF TEST RATE :0.20 GAL/HR <br /> DURATION , : 2 HOURS <br /> PERIODIC TEST FAIL TNK TST SIPHON BREAK OFF <br /> ALARM DISABLED TST EARLY STOP:DISABLED <br /> GROSS TEST FAIL DELIVERY DELAY 5 MIN LEAK TEST REPORT FORMAT <br /> PUMP THRESHOLD 10-00% <br /> ALARM DISABLED NORMAL <br /> PER TEST AVERAGING: OFF <br /> TANK TEST NOTIFY: OFF <br />