My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
290
>
2300 - Underground Storage Tank Program
>
PR0231438
>
COMPLIANCE INFO_2003-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2023 2:15:50 PM
Creation date
6/3/2020 9:49:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2015
RECORD_ID
PR0231438
PE
2361
FACILITY_ID
FA0003716
FACILITY_NAME
SUPER STOP GAS & LIQUOR*
STREET_NUMBER
290
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
22309101
CURRENT_STATUS
01
SITE_LOCATION
290 N MAIN ST STE C
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231438_290 N MAIN_2003-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
504
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 • <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility Super Stop Market Facility 290 N. Main St. #C Manteca, CA Inspection A r 29, 2014 <br /> Name: p p Address: Date: p <br /> VIOLATIONS <br /> # C1 C2 M Code Section HSC=CA Health and SafetyCode,CFR=Code of Federal Regulations <br /> C1=Class 1 violation;C2=Class 2 violation,M=Minor violation <br /> Non-Pressurized Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1,1984) (M1) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1,1984) (M1) <br /> Other Violations <br /> 999 Other: See attached"Continuation—Official Inspection Report'for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS 1,CLASS II,or MINOR-Notice to Comply) <br /> On site to witness the annual monitoring system certification testing and conduct the routine inspection. <br /> 104. Current financial responsibility documents have not been submitted to the EHD. The most recent <br /> copy submitted to EHD was dated 11-14-12. Current financial responsibility documents are required to <br /> be submitted annually. Immediately submit a copy of the financial responsibility documents to the EHD. <br /> Alternatively, log into CERS, upload the required information, and submit for review by the EHD. <br /> Complete by 5-29-14. <br /> 109. Annual monitoring system certification, leak detector testing, and spill container testing was <br /> performed on 4-30-13 and a test report has not been submitted to the EHD until 6-24-13. A copy of the <br /> test report must be submitted within 30 days of the tests. Continue to ensure that a copy of test reports <br /> are submitted to the EHD within 30 days of the tests. <br /> 201. The 4-30-13 Monitoring System Certification test results were not on site. These records shall be <br /> kept on site for at least 3 years. Immediately locate and maintain the test reports on site or available for <br /> review upon request. <br /> 206. The designated operator employee training for Mandeep Dua was not current. Training <br /> documentation indicates that Mandeep Dua was last trained by the facility designated operator on <br /> 4-24-13(not within the last twelve months. Mandeep Dua was working alone this morning at the store for <br /> about an hour. Mandeep Dua explained that he was not here when the facility designated operator <br /> performed the employee training on 4-22-14. The designated operator shall train facility employees for <br /> which he or she is responsible in the proper operation and maintenance of the UST system once every <br /> 12 months. <br /> The training shall include, but is not limited to: <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inspector. ecei B DTitle: <br /> I , ��s \uii� I ( 1 <br /> EHD 23-02 Rev 04/19/12 Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.