My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
290
>
2300 - Underground Storage Tank Program
>
PR0231438
>
COMPLIANCE INFO_2003-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2023 2:15:50 PM
Creation date
6/3/2020 9:49:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2015
RECORD_ID
PR0231438
PE
2361
FACILITY_ID
FA0003716
FACILITY_NAME
SUPER STOP GAS & LIQUOR*
STREET_NUMBER
290
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
22309101
CURRENT_STATUS
01
SITE_LOCATION
290 N MAIN ST STE C
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231438_290 N MAIN_2003-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
504
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 • <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sogov.org/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility Super Stop Facility 290 Main Street Manteca Inspection Mar 30 2012 <br /> Name: p p Address: + Date: <br /> VIOLATIONS <br /> # C1 C2 M Code section HSC=CA Health and Safety Code;CFR=Code of Federal Regulations <br /> C1=Class 1 violation,C2=Class 2 violation'M=Minor violation <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1,1984) (M1) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1,1984) (M1) <br /> 999 Other: See attached"Continuation—Official Inspection RepoW for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> 104. Current financial responsibility documents have not been submitted to the EHD. Last financial <br /> responsibility document was dated 12/2/10 and was due by 12/2/11. Current financial responsibility <br /> documents are required to be submitted annually. Complete and submit a copy of the financial <br /> responsibility to the EHD within 30 days of receiving this report. <br /> 109, 110. Annual monitoring system certification and leak detector testing were last performed on 3/8/11 <br /> and was due by 3/8/12. Monitoring certification was performed on 3/30/12 but was not completed due to <br /> the monitoring panel crashing and the technician did not have current VMI testing certification to test the <br /> leak detector. These tests are required once every 12 months. Immediately reschedule these tests and <br /> provide 48 hours notification to the EHD. Please be aware that a follow up inspection will be charged at <br /> our current hourly rate. A permit will be required for the cold start. <br /> 201. Facility does not have a alarm log. Records of all alarms shall be kept on site for at least 3 years. <br /> Immediately prepare and maintain an alarm log on site and submit copies to the EHD within 30 days of <br /> receiving this report. <br /> 202. Approved copies of the monitoring and response plans were not found on site. Copies of these <br /> plans shall be retained on site at all times. Immediately locate and retain a copy on site. <br /> 303. All the monitoring equipment connected to the veeder root panel may not working properly to <br /> ensure continuous monitoring of the tank system as required by CCR 2630(d). Veeder root monitoring <br /> panel crashed when fail safe was performed. Correct immediately by having a properly licensed, <br /> trained, and certified contractor replace the failed component with a functional component (LG 113-x <br /> listed, if applicable) and obtain a permit within one business day from the EHD. If the failed component <br /> can't be replaced immediately, there is a possibility that the UST system may be red tagged to prevent <br /> fuel inputs. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inspector: Received By: � � Title: <br /> N - /lel <br /> EHD 23-02 Rev 09/01/11 Page 3 UST INSPECTION REPORT <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.