Laserfiche WebLink
03-10-'11 09:40 FROM-West Star Envmt Inc, +559-277-0106 T-019 P0002/0006 F-807 <br /> Appendix VI <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://www.waterboards.ca.gov.) <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Judsdictfons Within the State of California <br /> Authority Cited:Chapter 6.7,Wealth and Safety Code;Chapter 16,Division 3, Title 23, California Code of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepoired for <br /> each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br /> owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General information <br /> Facility location Super Stop Bldg.No.: <br /> Site Address: 290 N Main city, -Manteca Zip: 95336 <br /> Facuity Contact person: Mandeep Contact Phone No.:(209)239-4475_ <br /> MakelModel of Monitoring System:—emc Date of Testing/SetVicirlg:_3-8-11 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appro riate boxes to Indicate spegTg a ui ment ins ectedrserviced: <br /> Tank ID:#1 Prem.uni. Tank ID!_43 87 Reg unl <br /> In-Tank Gouging Probe. Model: In-Tank Gauging Probe. Model; __ _ <br /> Model: <br /> 420 x Annular Space or Vault Sensor. Motlel: 7_ 2 <br /> x Annular Space or Vault Sensor. M R <br /> P <br /> 208 x Piping Sum /Trench Sensor(s). Model: _x Piping Sump/Trench 5ensor(s). Modeh� i» g pFill Sump$ansor(s). Model! Fill Sump Sensor(s). Model:x Mechanical Line Leak Detector. Model: FE Petro _ _ X Mechanical Line leak Detector. Model: <br /> Electronic Llne Leak Detector. Model; ❑ Electronic Line Leak Detector. Model: _ <br /> 0 Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> o Other(specify equipment and model in Section Eon Page 2}. 0 Others Ci a ui Ment a and model M Section I_on Pa 2. <br /> Tanic ib: 42 diesel. Tank ID: <br /> In-Tank Gauging Probe. Model: 0 In-Tank Gauging Probe. Model: <br /> x Annular Space or Vault Sensor, Model 420 ❑ Annular Space or Vault Sensor. Model: <br /> x Piping Sump I Trench Sensor(s). Model: 208 - _ 0 Piping Sump/Trench Sensor($). Model: <br /> Fill Sump Sensor(s). Model: ❑ f=ill Sump Sensor(s). Model: _.— <br /> x Mechanical Line Leak Detector. Model:—red jacket 11 Mechanical Line Leak Detector. Model; <br /> 0 T4nk Overfill/High-Level Sensor. Model: 0 Electronic line Leak Detector. Model: <br /> 0 Other(specify equipment type and model in Section E on Page 2). 0 Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other,(specify equipment_sand model In Section E on Pa e 2). <br /> Olspenserlo: #11-2 -- Dispenser 10:#7-8 <br /> Dispenser Containment Sensor(s). Model- _ __ ...____ ❑ Dispenser Containment Sensor(s), Model: . <br /> to shear vaive(s). 0 $hear Valve(s). <br /> X Dis user Containment Float(s)and Chain(s). X Dis enser Containment Floats and Chafn s. <br /> glspensor 11):_#3-4 Dispenser ID: <br /> Dispenser Containment Sensor(s). Model.___,208_ 0 Dispenser Containmern Sensor(s). Model: <br /> 0 Shear Vatve(s). ❑ Shear Valve(s). <br /> rODispertser <br /> Dispenser Containment Floats and Chain(s). x Dis enser containment Floats and Chain s- <br /> ser ID: 5-6 Dlspensor ID: #11-12 <br /> Containment Sensor(s). Model: — ❑ Dispenser Containment Sensor(s). Model-0 Shear Valve(s). <br /> a enser Containment Floats and Chains x Dispenser Containment Floats and Chains. <br /> `If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C« Certification - I cartify that the equipment identified in this document was Inspectediserviced In accordance with the manufacturers` <br /> guidelines. Attaoi+ed to this Certification Is Information(e.g.manufacturers'checklists)necessary to verify that this information Is Correct <br /> and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(vheck all that apply): a system set-up ❑Alar history report <br /> Technician Name(print): James(tom)Wall $ignature: _)a Axa <br /> Certification No.: 8029369 License.No.: 605142 <br /> Testing Company Name:West Star environmenlaf Phone No.:L,959, 277-9378 <br /> Testing Company Address: 6888 W JeAnifer Fresno ca 93722 Hate of Testing/Servicing: 3-8-11..-. <br /> Monitoring system Certification Page 1 of 4 <br /> 1 2/21/07 <br />