Laserfiche WebLink
E <br />P <br />SAN JOAQUIN COUNTY DATE. <br />VIS1432 <br />NVIRONMENTAL HEALTH DEPAR*NT PAGE e f 2 <br />'94 E. Weber Ave., Third Floor, Stockton, CA 95202 <br />(209) 468-3420 <br />UNDERGROUND STORAGE TANK (UST)_ PROGRAM INSPECTION REPORT <br />Facility Name_SUAer S4 A0ICP k Facility Address 2qO N. A44 i N �eG <br />Facilty Contact gI,IJt Phone #_ Z39 — 4Lf'7 <br />UST# S ProductQom_ UST#Product N41 UST# 1 Product A0y--L UST# Product <br />Overfill Prevention: ❑ Audible/Visual Mechanical Monitoring Panel: k l bA" FAC <br />Piping System: ❑ Gravity )(Pressure ❑ Suction Violations.XM1-RDet ❑ M2-Rprev ❑ M3 -Both <br />Automatic Pump Shut Down Satisfies CCR 2636 (f)(5): ❑ YesXNo Designated Operator: Soe'L C/'Rwferp <br />INSPECTION TYPE: Woutine Wonitoring Certification ❑Complaint ❑Install ❑Removal ❑Repair/Upgrade <br />COMPANY NAME: Cl %#r^elUIJ TECHNICIAN NAME4,74 PHONEtG1(6I g2%— 155 <br />VIOLATION(S) <br />The above facility is not in compliance with the following section(s) of Health & Safety Code (HSC) and/or <br />California Code of Regulations (CCR): <br />1 HSC 25284 <br />2 CCR 2637 <br />3 CCR 2711(b) & (c) <br />4 HSC 25292.2 <br />5 CCR 2632 (c)(2) <br />6 . CCR 2630 (d) <br />7 CCR 2637(b) <br />8 CCR 2636 (f)(1) <br />CCR 2636 (c)(1) <br />10 HSC 25291 (f) <br />11 HSC 25291(a)(2) <br />12 CCR 2635 (b)(1) <br />13 HSC 25284.2 <br />14 CCR 2635 (b)(2) <br />15 CCR 2631 (a) <br />16 CCR 2632 (d) <br />17 CCR 2712 (i) <br />187CCR 2712 (b) <br />19 CCR 2636 (f)(4) <br />20 CCR 2630 (d) <br />21 CCR 2630 (d) <br />22 CCR 2661 (f) <br />Permit to operate <br />23 <br />CCR 2643 (d) <br />Daily monitoring of suction <br />Secondary cont. testing <br />piping (pre -1/1/84) <br />Current State Forms A & B <br />24 <br />CCR 2636 (a) <br />Conventional suction piping <br />Certification of financial <br />shall have continuous <br />responsibility & CFO letter <br />monitoring & 20 containment <br />UST monitoring is present (M1) <br />25 <br />CCR 2643 (e) <br />Biennial tightness test of gravit, <br />UST system monitoring <br />piping (pre -1/1/84) <br />equipment is properly located to <br />26 <br />CCR 2643 (d) <br />Triennial line test for <br />detect a leak (M1) <br />conventional suction (pre - <br />UST system monitoring <br />1/1/84) (M1) <br />equipment is operational (M1) <br />27 <br />CCR 2661 <br />Permit to repair UST system <br />Continuous monitoring system <br />28 <br />HSC 25286 (a) <br />Permit to alter monitoring <br />for underground piping & UDC <br />system <br />is present (M1) <br />29 <br />HSC 25298 (a) <br />Illegal abandonment of UST <br />All releases in secondary piping <br />system <br />flow to a collection sump <br />30 <br />HSC 25298 (b) <br />Permit to temporarily close US - <br />Line leak detector(s) (M1) <br />system <br />Secondary containment for <br />31 <br />HSC 25298 (c) <br />Permit to close UST system <br />UST is tight <br />32 <br />HSC 25292.1 <br />UST system is operated to <br />Spill container (M2) <br />prevent unauthorized release <br />Annual spill container testing <br />33 <br />CCR 2650 <br />Recording/reporting <br />Overfill prevention system (M2) <br />unauthorized release (M1) <br />Primary containment is product-, <br />34 <br />HSC 25291 (e) <br />Water in 20 cont analyzed and <br />tight <br />properly disposed of <br />Monitoring & response plan <br />35 <br />CCR 2640 (e) <br />Single wall component within <br />Monitoring & response plan is <br />1000' of Public Well, no ELD <br />on site <br />36 <br />CCR 2635(a)(2)(A) Cathodic protection testing & <br />Maintenance & monitoring <br />60 day inspection log (M2) <br />records (M1) <br />37 <br />H&SC 25299(a)(9) Disabling leak detect. Devices <br />Annual line tightness test <br />38 <br />CCR 2715(a) <br />Statement from UST owner <br />Annual line leak detector test <br />39 <br />CCR 2715(c) <br />Monthly inspection by D.O, <br />(M1) <br />40 <br />CCR 2715 (f) <br />D.O. trained employees <br />Annual monitoring certification <br />41 <br />Violation(s) not listed above <br />Repair for tank/piping has had <br />tightness test (M2) <br />EHD INSPECTOR: KA" VONJ Rt.� PHONE: Lib 8- 41 9 Lf 9 1 <br />RECEIVED BY: \&k / TITLE: RW" <br />Septic System: 0 Serves z 20 persons/day 0 Receives other than sanit:Yry waste <br />Other Disposal Units Identified: 0 Dry wells/French Drains <br />1AUnits\Unit-IInUST\UST inspection8.19.04.DOC <br />