Laserfiche WebLink
Underground Storage Tank Monitoring Program <br /> 1.Operator/Site Number: JAMES J. MCCARTHY Cost Center#255417 RE#30877 <br /> 2. Site Address and Phone Number: 1700 EAST YOSEMITE AVE MANTECA, CA 95336 ph. (209)823-7676 <br /> 4. Frequency of Monitoring Method and location Where Monitoring will be Performed: <br /> Tanks: Tank(s)01 02 are monitored continuously using an electronic probe in the interstitial space of the tank. <br /> Piping: Pipe(s)01 02 are equipped with continuous mechanical line leak detectors. Pipe(s)0102 are monitored continuously by a liquid-detecting probe located in the turbine sump. <br /> Dispenser: Dispenser pans are equipped with continuous electronic monitoring and programmed for positive shut down. <br /> 5. Name(s)and title(s)of the person(s) responsible for performing the monitoring and/or maintaining the equipment: <br /> Operator Name and Number: JAMES J. MCCARTHY - (209)823-7676 <br /> Maintenance: ConocoPhillips Service Contact Center - 1-866-805-4357 <br /> — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — <br /> 6. Reporting Format: <br /> The monitor will be certified annually and a report generated and provided to the operator. The operator is to report all audible or visual alarm conditions that may indicate a potential release to <br /> the ConocoPhillips Field Representative,as well as the responsible parry for maintenance listed under#5. In the event of a test failure,the specific piece(s)of equipment are taken out of service <br /> and proper reporting procedures followed. The operator is to report all suspected and confirmed releases to the ConocoPhillips Field Representative,as well as the responsible party for <br /> maintenance listed under#5. <br /> 7. State the Preventative Maintenance Schedule for the Monitoring Equipment <br /> The electronic monitoring system is certified annually to be functioning per manufacturer instructions by a properly trained and certified third-party contractor. Repairs are made by the <br /> responsible party listed under#5 upon notification by the station operator. The station operator is responsible for maintaining copies of testing results and repair records on site and available for <br /> agency inspectors. The 3rd-party testing requirements and frequencies for the tank system are summarized below. <br /> Contractor UST System Testing RequirementslFrequency <br /> Contractor testing of the primary tank is not required. <br /> The tank secondary containment is tested per manufacturer's specifcations every 3 years in Contractor testing of the primary piping is not required. <br /> accordance with CCR Title 23 Section 2637. <br /> Fuel and vapor spill buckets require annual testing. Secondary containment testing for piping,turbine sumps and dispenser pans is <br /> _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _conducted everL3 ears p®r man_ufacturer's specification under CCR Title 23. <br /> 8. Describe the Training Needed for the Operation of Both the Tank System and the Monitoring Equipment: <br /> The operator has been trained to check the tank system and/or monitor daily for proper operation.Training topics include performing daily/monthly inventory reconciliation,inspection of the <br /> monitoring system to ensure it is operating properly and not in alarm,periodic inspection of under-dispenser for leaks,inspection of fill and vapor spill buckets,inspection of hoses,nozzles,and <br /> other ancillary tank system equipment. If the tank system and/or monitor is not functioning correctly,the operator has been instructed to repair the equipment(if appropriate)or contact the <br /> responsible party for Maintenance listed under item#5 for repairs. <br /> — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — <br /> 9. Summary of Site Operator Requirements: <br /> For pipes monitored electronically,the site operator is to call the specified maintenance company to report monitoring alarms and maintain a record of all monitoring alarms and repairs. For <br /> double wall tanks monitored by interstitial probes,the monitoring equipment must be continously operational with probes in place. Report all non-inventory monitoring alarms to the specified <br /> maintenance company and keep a record of alarms and repair work performed. All sites are responsible for maintaining daily and monthly inventory reconciliation records and notifying the <br /> ConocoPhillips Field Representative and the Regional Environmental Compliance Specialist for inventory variances greater than the regulatory limit. <br /> 255417/30877 JAMES J.MCCARTHY, 1700 EAST YOSEMITE AVE,MANTECA,CA 95336 Date Printed: 09/08/2003 <br />