My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1700
>
2300 - Underground Storage Tank Program
>
PR0231454
>
COMPLIANCE INFO_2007-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2023 11:52:51 AM
Creation date
6/3/2020 9:49:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2018
RECORD_ID
PR0231454
PE
2361
FACILITY_ID
FA0003796
FACILITY_NAME
Manteca Valero
STREET_NUMBER
1700
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22802002
CURRENT_STATUS
01
SITE_LOCATION
1700 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231454_1700 E YOSEMITE_2007-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
466
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
03/18/2008 12:07 FAX 19257561227 QUEST GSM 9004 <br /> UJWIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN— e 2 of 2). <br /> I'M MENNONEEMENNIM <br /> UDC MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) <br /> ® I.CONTINUOUS ELECTRONIC MONITORING ❑ 2.FLOAT AND CHAIN ASSEMBLY ❑ 3.ELECTRONIC STAND-ALONE 490.54". <br /> 4.NO DISPENSERS 99.OTH_ERS CC 490.546. <br /> LEAK MONITOR MANUFACTURER: Veede►-Root 491-11. MODEL#: TLS-350 490-56. <br /> LEAK SENSOR MANUFACTURER: Veedsr-Root 490-57• MODEL#(S): 794380-208 490-58, <br /> DETECTION OF A LEAK INTO THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS. ® a.YES ❑ b.NO 49°-59. <br /> UDC LEAK ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑ b.NO 490-60. <br /> FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑ b.NO 490.61. <br /> UDC MONITORING STOPS THE FLOW OF PRODUCT AT THE DISPENSER. ® a YES ❑ b.NO 490.62. <br /> ---•-- <br /> UDC CONSTRUCTION IS: ® 1.SINGLE WALL ❑ 2.DOUBLE WALL 490.63. <br /> IF DOUBLE WALL: 49°-64'. <br /> UDC INTERSTITIAL SPACE IS MONITORED BY: ❑ a.LIQUID ❑ b.PRESSURE ❑ c.VACUUM <br /> A LEAK WITHIN THE SECONDARY CONTAINMENT OF THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS. ❑ a.YES ❑ b.NO 490.64b. <br /> u; <br /> ❑ I.ELD TESTING: THIS FACILITY HAS BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT ENHANCE D 490-65. <br /> L'AK PETE <br /> UD MUST BE PERFORMED. PERIODIC PLD IS PERFORMED EVERY 36 MONTHS AS REQUIRED.j23 CCa§2644.1) <br /> ® 2.SECONDARY CONTAINMENT COMPONENTS ARE TESTED EVERY 36 MONTHS. 490 <br /> ® 3.SPILL BUCKETS ARE TESTED ANNUALLY. 490!67. <br /> tiE �t 1 <br /> The following moaitoring/maintenance records are kept for this facility: 490.68. <br /> ® a.ALARM LOGS ® b.VISUAL INSPECTION RECORDS ® c.TANK INTEGRITY TESTING RESULTS <br /> ❑ d.SIR TESTING RESULTS(and supporting documentation records) ❑ e.TANK GAUGING RESULTS(and supporting documentation records) <br /> ❑ f.ATG TESTING RESULTS(and supporting documentation records) ❑ g.CORROSION PROTECTION 60-DAY LOGS <br /> h.EQUIPMENT MAINTENANCE AND CALIBRATION RECORDS <br /> 001%ME I• 1;, <br /> "Paw WE <br /> ® Personnel with UST monitoring responsibilities are familiar with all of the following documents relevant to their job duties: 490-69a- <br /> REFERENCE DOCUMENTS MAINTAINED AT FACILITY(Check all that apply) <br /> ® THIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required) 490-69b <br /> ® OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required) 49f"9e <br /> ❑ CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS 490.69d. <br /> ❑ CALIFORNIA UNDERGROUND STORAGE TANK LAW 49049c• <br /> ❑ STATF. WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND 490-69f• <br /> STATISTICAL INVENTORY RECONCILIATION" <br /> ❑ SWRCB PUBLICATION:"UNDERSTANDING AUTOMATIC TANK GAUGING SYSTEMS" 490 698. <br /> 490.69h. <br /> ❑ OTHER(Specify): 490.691. <br /> ® This facility has a"Designated UST Operator"who has passed the California UST System Operator Exam administered by the International Code Council 490-70. <br /> (ICC). The "Designated UST Operator"will train facility employees in the proper operation and maintenance of the UST systems annually,and within 30 <br /> days of hire.This training will include,but is not limited to,the following: <br /> D Operation of the UST systems in a manner consistent with the facility's best management practices. <br /> Y The facility employee's role with regard to the monitoring equipment as specified in this UST Monitoring Plan. <br /> Y The facility employee's role with regard to spills and overfills as specified in We facility's UST Response Plan. <br /> Name(s)of contact persons)for emergencies and monitoring alarms. <br /> 7 <br /> 01MIN IN <br /> Provide additional comments here or indicate how many pages with additional information on specific monitoring procedures are attached to this plan. 490.71. <br /> OYerfili Protection:Mechanical Flapper 95%of tank capacity <br /> T <br /> The UST Owner/Operator is responsible for ensuring that: 3.)the daily/routine UST monitoring activities and maintenance of UST leak detection equipment covered <br /> .b t�tis Blau occuJ 2�all conditions Wet indicate ossiblo release are iuvesti eted;ander all monitoring rewrAi are maintained_probe <br /> THE FOLLOWING PERSON(S)ARE RESPONSIBLE FOR PERFORMING THE MONITORING AND EQUIPMENT MAINTENANCE: <br /> NAME: Terry Dosanjh 490.72• TITLE: Manager 490.73. <br /> NAME: Sunny Shullar 490-74. TSE: President 490.75. <br /> The Designated UST Operator shall perform a monthly visual inspection of the facility,provide a report to We owner/operator,and inform the owner/operator of any <br /> conditions that and follow-URaction. <br /> d <br /> ry' I r �l'r: <br /> lffr. <br /> CERTIFICATION:I certify that the information provided herein is true and accurate to the best of my knowledge. <br /> APPLICANT SIGNATURE i DATE: 490-77• <br /> REPRESENTING:- .? Owner 2. 'lir OwmlOpmw 3.AurheriadRe n0- Uifiveof Owner 490-76. <br /> APPLICANT NAME(print): 490-79' APPLICANT TITLE: 490-79. <br /> Sunny Bhullar President <br /> UPCF UST-D(!21200'1).3/4 wvvw.unidoes.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.