My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1996-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
341
>
2300 - Underground Storage Tank Program
>
PR0231477
>
COMPLIANCE INFO_1996-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 4:42:40 PM
Creation date
6/3/2020 9:50:03 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996-2005
RECORD_ID
PR0231477
PE
2361
FACILITY_ID
FA0003753
FACILITY_NAME
RIPON SHELL*
STREET_NUMBER
341
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
RIPON
Zip
95366
APN
26114007
CURRENT_STATUS
01
SITE_LOCATION
341 E MAIN ST
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231477_341 E MAIN_1996-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
309
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�w-_ <br /> UNIFIED PROGRAM CONSOLIDATED FORM <br /> TANKS <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 1 (two pages per tank) <br /> Past Z rd <br /> 1 TYPE OF ACTION Fl. NEW SITE PERMIT F 4. AMENDED PERMIT F 5. CHANGE OF INFORMATION) r 6. TEMPORARY SITE CLOSURE <br /> (Check one item only)F 2. OPERATOR CHANGE r 7. PERMANENTLY CLOSED ON SITE <br /> X 3. RENEWAL PERMIT (Spocity rowan-forlocal uce only) (Specity change-lar local use only) r 8- TANI'K REMOVED 430 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As)3 FACILITY ID# 1 <br /> Ripon Shell <br /> LOCATION WITHIN SITE(Optional)431 341 E.Main Street,Ripon,CA 95366 <br /> .TANK DESCRIPTION (A scaled plot plan with the location of the UST system includ!ng bm s and landmarks shall be submitted to the focal agency) <br /> TANK ID# r Leo ( 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK F Yes X No 434 <br /> 135816-Regular Xerxes If AYes-,complete one page for each compartment. <br /> DATE INSTALLED(YEARIMO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 1996 15,000 One <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> II.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> X 1. MOTOR VEHICLE FUEL X 1a. REGULAR UNLEADED F 2. LEADED r 5. JET FUEL <br /> (If marked,complete Petroleum Type) F 1b. PREMIUM UNLEADED r 3. DIESEL F 6. AVIATION FUEL <br /> r 2. NON-FUEL PETROLEUM F 1c.MIDGRADE UNLEADED F 4. GASOHOL r99. OTHER <br /> F 3. CHEMICAL PRODUCI <br /> F 4. HAZARDOUS WASTE(Includes COMMON NAME(from Hazardous Matenals Inventory page)441 CAS#(from Hazardous Materials Inventory page) 442 <br /> Used Oi✓) <br /> F95 UNKNOWN <br /> Ill.TANK CONSTRUCTION <br /> TYPE OF TANK r 1. SINGLE WALL F 3. SINGLE WALL WITH r 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one item only) X2. DOUBLE WALL EXTERIOR MEMBRANE LINER r95. UNKNOWN <br /> F 4. SINGLE WALL IN A VAULT <br /> F 99. OTHER <br /> TANK MATERIAL-primary tank F 1. BARE STEEL X3. FIBERGLASS I PLASTIC F 5. CONCRETE r'95. UNKNOWN 444 <br /> (Check ono itam only) F 2. STAINLESS STEEL F 4. STEEL CLAD WIFIBERGLASS F 8. FRP COMPATIBLE W2100%METHANOL F 99. OTHER <br /> REINFORCED PLASTIC(FRP) <br /> TANK MATERIAL.secondary r 1. BARE STEEL X3_ FIBERGLASS f PLASTIC r 6. FRP COMPATIBLE W/100%METHANOL r 95. UNKNOWN 445 <br /> tank <br /> F 2. STAINLESS STEEL F 4. STEEL CLAD W(FIBERGLASS F 9. FRP NON-CORRODIBLE JACKET F 99. OTHER <br /> (Check one item only) REINFORCED PLASTIC(FRP) <br /> F 10. COATED STEEL <br /> F 5. CONCRETE <br /> TANK INTERIOR LINING F 1. RUBBER LINED F 3, EPDXY LINING F 5. GLASS LINING F 95. UNKNOWN446 DATE INSTALLED 447 <br /> OR COATING <br /> r 2. ALKYD LINING F 4. PHENOLIC LINING X 6. UNLINED F 99. OTHER <br /> (Check one item only) (For local use only) <br /> OTHER CORROSION I' 1. MANUFACTURED X 3. FIBERGLASS REINFORCED PLASTIC r95 UNKNOWN 448 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE <br /> CATHODIC F 4. IMPRESSED CURRENT F99, OTHER <br /> (Check one item only) PROTECTION (For focaf use only) <br /> F 2 SACRIFICIAL ANODE <br /> SPILL AND OVERFILL YEAR INSTALLED TYPE(For local use only)451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> 450 <br /> (Check all that apply) X1. SPILL CONTAINMENT_1996_ X 1. ALARM _199$_X 3. FILL TUBE SHUT OFF VALVE_1996_ <br /> X 2. DROP TUBE 1996 F 2. BALL FLOAT F 4. EXEMPT <br /> X 3. STRIKER PLATE 1996 <br /> IV. TANK LEAK DETECTION (A description of the monttonng program shall be suomiffed to the local agency) <br /> IF SINGLE WALL TANK(Check all that apply): 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER(Check one item only): 454 <br /> r 1, VISUAL(EXPOSED PORTION ONLY) F 5. MANUAL TANK GAUGING(MTG) F 1 VISUAL(SINGLE WALL IN VAULT ONLY) <br /> F 2. AUTOMATIC TANK GAUGING(ATG) r 6. VAUOSE ZONE X2. CONTINUOUS INTERSTITIAL MONITORING <br /> r 3. CONTINUOUS ATG F 7. GROUNDWATER F 3. MANUAL MONITORING <br /> F 4. STATISTICAL INVENTORY RECONCILIATION(SIR)+ F 8. TANK TESTING <br /> BIENNIAL TANK TESTING r 99. OTHER <br /> V.TANK CLOSURE INFORMATION 1 PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR(MOIDAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> gallons Fye. F No <br /> UPCF(1/99 revised) Formerly SVVRCB Form B <br /> 6 <br /> 6 'd b969-GL9-602 TLysegnjeW •1 aonig dS2 =E0 20 62 .add <br />
The URL can be used to link to this page
Your browser does not support the video tag.