FACILITY_NAME
RIPON SHELL*
STREET_NUMBER
341
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
RIPON
Zip
95366
APN
26114007
CURRENT_STATUS
01
SITE_LOCATION
341 E MAIN ST
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231477_341 E MAIN_1996-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
309
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDU ANK/LINE/LEAK DETECTOR T REPORT <br /> TEST DATE: 03/09/98 WORK ORDER NUMBER: 2203767 <br /> CLIENT: SHELL OIL COMPANY SITE: SHELL 204-6522-0307 <br /> MEEM EMM <br /> Tank ID: i Material: Dw FIBERG Bottom to top fill in inches: 158.0 <br /> Product: PREMIUM Tank manifolded: No Bottom to grade fill in inches: 165.0 <br /> Capacity in gallons: 14,976 Vent manifolded: No Fill pipe length in inches: 38.0 <br /> Diameter in inches: 120.00 Vapor recovery manifolded: YES Fill pipe diameter in inches: 4.0 <br /> Length in inches: 338 Impact Valves Operational: Y Stage I vapor recovery: DUAL <br /> Tank age(years): Overfill protection: YES Stage II vapor recovery: ASSIST <br /> Fuel pure rating: Overspill protection: YES Installed: ATG <br /> COMMENTS CP installed on: <br /> PSI at tank bottom: New/passed Failed/replaced New/passed Failed/replaced <br /> Fluid level in inches: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> UFT/OFT: Make:FE PETRO <br /> Fluid volume in gallons: Model: P.L.D. <br /> Tank water level in inches: S/N: J0261 <br /> Test time: Open time in sec: 5.00 <br /> Number of thermisters: Holding psi: 11 <br /> Specific gravity: Resiliancy cc: 185 <br /> Water table depth in inches: Test leak rate ml/m: 189.0 <br /> Determined by(method): Metering psi: 10 <br /> Leak rate in gph: Calib. leak in gph: 3.00 <br /> Result: Results: PASS <br /> COMMENTS COMMENTS <br /> Test time: Material: DW FIBERG <br /> Ullage volume: Diameter tin): 2.0 <br /> Ullage pressure: Length(ft): 45.0 <br /> Results: Test psi: 50 <br /> Bleedback cc: 45 <br /> DATA FOR UTS-4T ONLY: Test time(min): 30 <br /> Test 1:Start time: 09:15 <br /> Time of test 1: Finish psi: 48 <br /> Temperature: Vol change cc: 9 <br /> Test 2:Start time: 09:25 <br /> Flow rate(cfh): Finish psi: so <br /> Time of test 2: Vol change cc: 0 <br /> Test 3:Start time: 09:35 <br /> Temperature: Finish psi: 50 <br /> Flow rate(cfh): Vol change cc: o <br /> Time of test 3: Final gph: 0.005 <br /> Temperature: Result: Pass <br /> Flow rate(cfh): Pump type: PRESSURE <br /> COMMENTS Pump make: RED JACKET <br /> COMMENTS <br /> Draft 03/11/98 13:44 MSHAW <br /> 8900 SHOAL CREEK,BUILDING 200,AUSTIN,TEXAS 78757(512)451-6334 <br />