My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1996-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
341
>
2300 - Underground Storage Tank Program
>
PR0231477
>
COMPLIANCE INFO_1996-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 4:42:40 PM
Creation date
6/3/2020 9:50:03 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996-2005
RECORD_ID
PR0231477
PE
2361
FACILITY_ID
FA0003753
FACILITY_NAME
RIPON SHELL*
STREET_NUMBER
341
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
RIPON
Zip
95366
APN
26114007
CURRENT_STATUS
01
SITE_LOCATION
341 E MAIN ST
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231477_341 E MAIN_1996-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
309
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JAN-11-2005 21:14 SERVICE STATION SYSTEM 408 971 0135 P.06 <br /> Monitorinj Systemi e t fertification <br /> Por Use By All Jurisdiction.• Within The State of California <br /> Authority Citeel: Chapter 6.7,Health and,Sa}ety Cade; Chapter 16,Division 3, Title 23, California Code.o Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or repot-t must be <br /> prepared for each monitori? system control panel by the technician who performs the work. A copy of this form must be provided <br /> to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST system <br /> within 30 days of test date. <br /> A. General Information <br /> Facility Nanic: i2iRon Sheii -- Bldg,No.: <br /> Site Address: 341 E. Main St. a Hwy.99 City. Ripon, CA Zip: 95366 <br /> Facility Contact Person: T__. Contact Phone No.: (209) 599-4454 <br /> Make/Model of Monitoring System: V/R Simplicity Date of Testing/Servicing: <br /> B. Inventory of Equipment Tested/Certified �l711q' <br /> Check the appropriate hoxes to indicate specific equipment inspected/serviced: <br /> Tank ID•01-Reg. Tank ID• 02-Prem <br /> ❑ In-Tank Gauging Probe. Mudel: VR 847390.109 13 in-Tank Gauging Probe. Model: VR 847390-109 <br /> ❑ Annular Space or Vault Sensor. Model VR 794380.102 ® Annular Space or Vault Sensor. Model: VR 794380.302 <br /> p Piping Sump\Trench Sensor(s). Model: VR 794380-208 ❑ Piping Sump\'french Sensor(s), Model: VR 794180-208 <br /> (3 Fill Sump Sensor(s). Model: None ❑ Fill Sump Sensor(s). Model; None <br /> ❑ Mechanical Linc Leak Detector. Model' None ❑ MechanicaI Linc Leak Detector. Model: None <br /> Electronic Line Leak Detector. Model: VR Series 2424 Electronic Line Leak Detector. Model: VR Series 8494 <br /> Q Tank Overfill\High-Level Sensor. Model: None ❑ Tank Overfill\High-Level Sensor, Model: Nona <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Sectiun E on Page 2) <br /> Tank 1D' Tank ID: <br /> ❑ In-Tank Gauging Probe. Model; ? p in-Tank Gauging Probe, Model: ? _ <br /> ® Annular Space or Vault Sensor. Model: ? El Annular Space or Vault Sensor. Model: 7 <br /> ❑ Piping Sump\Wrench Sensor(s), Model: ? ❑ Piping Sump\Trench Sensor(s). Model: ? <br /> ❑ Fill Sump Sensor W. Model: ? ❑ Fill Sump Sensor(s). Model: 7 <br /> ❑ Mechanical(Arc Leak Detector. Model: ? ❑ Mechanical Litre Leak Detector. Model ? <br /> ❑ Electronic Linc Leak Detector. Model: 7 Q Electronic Line Leak Detector. Model: ? <br /> Q Tank Overfill\High-Level Sensor. Model: ? ❑ 'Tank Overfill\High•Level Sensor, Model: ? <br /> C) Othcr(Specify eyuiprlleflt type and moCc1 in;Section;L:on Nage 2), O Other(specify eyuipilient type and model in Scam F.On Page 2). <br /> Dispenser ID: 01.02 Dispenser ID; 03.04 <br /> ❑ Dispenser Containment Sensor(s), Model: VR 794380-322 ❑ Dispenser Ccmtainment Sensor(S). Model: VR 794380-322 <br /> Ll <br /> 13 Dispenser Containment Float(s)and Chain(s). p I)ispenser Containment Float(s)and Chain(s). <br /> Dispenser ID, 05-06 Dispenser ID- 07-08 <br /> ❑ Dispenser Containment Sensor(s). Model; VR 794180.322 Ll Dispenser Containment Scnsnr(s). Model: VR 754390.322 <br /> ❑ Shear Valve(s), [3 Shear Valve(s). <br /> 0 Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s), <br /> Dispenser J[D; Dispenser ID, <br /> ❑ Dispenser Containment Sensor(s). Model: 7 1 n Dispenser Containment Sensor(s). Model: 7 <br /> A Shear Valve(s), ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s), <br /> *If the facility contains more tanks or dispensers,copy this fonn.Inchtdc information for every tank and dispenser at the facility <br /> C.Certification- I certify that the equipment identified in this document was Inspectediserviced in accordance with the <br /> manufacturer's guidelines. Attached to this Certification is information(e.g.manufactures'checklists)necessary to verify that this <br /> information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br /> reports,l have also attached a copy of the; (check all that appl,V)- [3 Systemset-up C Ain istory report <br /> Technician Name(print)-S6S--Rrl"cTc U5 Vic .. - Signature: <br /> Certification No,- _ C)(J.`{.JS—L_ License.No. 5184 <br /> Testing Company Name: Ser. Sta.SYS, Phone No. 408)971-2445 <br /> Site Address: 341 E. Main$t.!M Hwy. 99 __ Date of Tcsting/Servicing,,,���`j <br />
The URL can be used to link to this page
Your browser does not support the video tag.