H I RT TM Mini Processor <br /> DESCRIPTION <br /> This processor functions to keep a balance type Stage II vapor recovery system <br /> within the allowable CARB E.V.R. UST pressure criteria. The unit employs a <br /> specialized turbine that collects only excess vapor from the USTs. A unique <br /> combustor converts the excess vapor into harmless carbon dioxide (CO2) and <br /> water vapor(1-120). <br /> OPERATION <br /> The processor automatically operates intermittently as required above the <br /> j particular setpoint. A vacuum sensor located within the unit's cabinet determines <br /> the setpoint and is factory calibrated at -0.3 to -0.4 "w.c. In the event of a <br /> malfunction, an integral flame safeguard closes to effectively prevent the <br /> emission of vapor to the atmosphere. <br /> SPECIFICATIONS <br /> MODEL: VCS 100 <br /> SERVICE: Outdoor, non hazardous area <br /> ELECTRICAL: 120 VAC, 3 Ampere, intermittent <br /> VAPOR PIPE CONNECTION: 3/4" NPT <br /> WEIGHT: 80 lbs. <br />