Laserfiche WebLink
• SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.s*gov.org/ehd/unitiii.htmi <br />CONTINUATION FORM <br />Page: 3 of 6' <br />OFFICIAL INSPECTION REPORT <br />Date: 01/05/11 <br />Facility Address: 1097 Yosemite Avenue, Escalon <br />Program: UST <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS 11, or MINOR -Notice to Com <br />UST Inspection Report <br />3. UST facility and tank forms on file with the EHD are not current. Any change of information on these <br />forms must be submitted to the EHD within 30 days of the changes. Immediately complete and submit a <br />copy of the facility and tank forms to the EHD within 30 days of receiving this report. Complete a <br />separate tank form for each tank. <br />4. A Current financial responsibility documents have not been submitted to the EHD. Current financial <br />responsibility documents are required to be submitted annually. Last financial responsibility certification <br />was submitted on 12/23/09 and the next one was due by 12/23/10. Complete and submit a copy of the <br />financial responsibility within 30 days of receiving this report. <br />5 & 6. Current approved copies of the monitoring and response plans were not found on site. The <br />monitoring and response plans must be current and approved by the EHD. Complete and submit a copy <br />of the monitoring and response plans for approval by the EHD within 30 days of receiving this report. An <br />approved copy will be returned for your records. <br />7. The alarm log and a maintenance log were not found on site. These records shall be kept on site for <br />at least 3 years . Immediately locate and maintain the alarm and maintenance log on site and submit <br />copies to the EHD within 30 days of receiving this report. <br />15. The secondary containment test results indica fe a failure under dispenser containment (UDC)1/2, <br />3/4, 5/6, 7/8, 87 secondary line run #2, #3, A and secondary line run #1. All secondary containment for <br />the UST system must be tight. Immediately have a properly licensed, trained, and certified contractor <br />repair or replace the failed component under permit and inspection of the EHD and submit passing <br />results to this office. <br />23a. A designated operator employed by Franzen -Hill (Steve Zwahlen) performing designated operator <br />monthly inspections did not provide notification to the EHD within 30 days of the change. Steve Zwahlen <br />also signed on designated operator monthly report prepared by Tony Murch and Terry Hudson. Any <br />changes shall be reported to the EHD with 30 days. Submit notification to the EHD identifying all the <br />designated operators for this facility within 30 days of receiving this report. <br />ALL EHD STAFF TIME ASSOCIATED NIITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE 131111 Fn AT THE CURRENT HOURLY RATE (;122). <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />EHD Inspector. <br />Received By: �" <br />Title: V <br />EHD 23-02-003 Rev 08/10/10 CONTINUATION FORM <br />