My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015-2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1097
>
2300 - Underground Storage Tank Program
>
PR0231497
>
COMPLIANCE INFO_2015-2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2023 2:05:16 PM
Creation date
6/3/2020 9:50:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015-2019
RECORD_ID
PR0231497
PE
2361
FACILITY_ID
FA0000279
FACILITY_NAME
ESCALON MINI MART
STREET_NUMBER
1097
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22510001
CURRENT_STATUS
01
SITE_LOCATION
1097 YOSEMITE AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231497_1097 YOSEMITE_2015-2019.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
349
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br />Aek <br />lqw <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />ESCALON MINI MART <br />Facility Address: <br />1097 YOSEMITE AVE, ESCALON <br />Date: <br />December 13, 2017 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />210 <br />CCR 2715(e) Designated operator monthly inspection reports not maintained on site for at least 12 months. <br />The February 2017, March 2017, July 2017 and August 2017 designated operator monthly inspection reports were <br />not found on site during the inspection. The designated operator, Felix Ramirez, was on site during the inspection <br />and printed them out. Designated operator monthly inspection reports for the previous twelve months shall be <br />retained on site. <br />This was corrected on site. <br />This is a Class 11 violation. <br />301 <br />HSC 25292.1 UST system is not operated to prevent unauthorized release, including spills and overfills. <br />During the inspection, liquid was observed on top of the filters in the 8/7 under dispenser containment unit. Liquid <br />was observed on the piping below the fuel filter as well. The piping and the fuel filter were wet. The technician's <br />assistant on site put his hand on the filter and scraped his finger along the surface. There was a brown tar like <br />substance that came off with a liquid. Both the technician, Felix Ramirez, and his assistant said that the liquid was <br />probably coming from the fuel filter. The technician assistant wiped off the liquid on the filter. The underground <br />storage tank system shall be operated to prevent unauthorized releases. Immediately make a determination to see <br />where the liquid is coming from and send the repair records to EHD. <br />This is a repeat violation, Class 11. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by January 12,2018. <br />Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br />documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br />Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br />applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br />Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br />AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br />THIS FACILITY BACK INTO COMPLIANCE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Received by: Date: December 13, 2017 <br />Inspector: <br />Inspector Phone: <br />Printed Name and Title: <br />JOHN ALANIZ, EH Specialist <br />(209) 468-3147 <br />Bill Singh, Owner <br />FA0000279 PR0231497 SCO01 12/13/2017 <br />EHD 23-01 Rev. 09/22/16 Page 6 of 6 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.