My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997-2002
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
16500
>
2300 - Underground Storage Tank Program
>
PR0231554
>
COMPLIANCE INFO_1997-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2021 4:00:13 PM
Creation date
6/3/2020 9:50:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-2002
RECORD_ID
PR0231554
PE
2361
FACILITY_ID
FA0005678
FACILITY_NAME
LATHROP SHELL
STREET_NUMBER
16500
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
LATHROP
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
16500 S HARLAN RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231554_16500 S HARLAN_1997-2002.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
482
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> e <br /> t , <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16,Division 3,Title 23,California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be eared <br /> for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator..The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 <br /> days of test date. <br /> A. General Informatio <br /> Facility Name: ir�� Bldg.No.- <br /> Site Address: City: SLA,,--s Zip:95330 <br /> 30 <br /> Facility Contact Person: Contact Phone No.:(c24 )�S <br /> MakelModel of Monitoring Systeri Date of Testing/Servicing: /0//�L/IC4— <br /> B. Inventory of Equipment Tested/Certified <br /> Check the a ro riate taxes to indicate specific equipment Ins iced: <br /> Tank ID: Tank ID: <br /> In Tank Gauging Probe. Model: In Tank Gauging Probe. Model: hd <br /> Annular Space or Vault Sensor. Model: 4[A Annular Space or Vault Sensor. Model: 409 <br /> d$ Piping Sump/Trench Sensor(s). Model: ICF(- ,Q� Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> -9 Mechanical Line Leak Detector. Model: Mechanical Lane Leak Detector. Model: z4ffC <br /> ❑ Electronic Line L.eak'Detector. Model: Electronic Lane Leak Detector. Model: <br /> AP Tank Overfill/High-Level Sensor. Model:Xa Its Tank Overfill/High-Level Sensor. Model: lot/ <br /> ❑ Other(specify Equiernent=and model in Section E on Pae 2). Other 422Lif <br /> X equipment type and model in Section E on PaLe 2). <br /> Tank ID• Tank ID: <br /> ❑ In-Tank Gauging Probe. Model: ❑ In-Tank Gauging Probe. Model: <br /> ❑ Annular Space or Vault Sensor. Model: ❑ Annular Space or Vault Sensor. Model: <br /> ❑ Piping Sump/Trench Sensor(s). Model: ❑ Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical lane Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify ui anent=and model in Section E on Page 2). ❑ Other(specify ui men[type and model in Section E on PaLe 2). <br /> Dispenser ID: t tz' Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s). Model ❑ Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and n(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: —131-111 Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑Dis enser Containment Floats)and Chain(s). ❑ Dis22nser Containment Float(s)and Chain(s). <br /> •If the facility contains more tanks or dispensers,copy this form Include information for every tank and dispenser at the facility. <br /> C. Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e g. manufacturers' checklists) necessary to verify that this information is <br /> correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also <br /> attached a copy of the report;(check all apply): ,�System set-up Af Alarm hist ry report <br /> Technician Name(print): S'rs�" Signature: <br /> No.: CCr 7. 5 ! <br /> Certification I\o.: 'S_.. `� • �� License.No.: t_�C3-(s/� <br /> Testing Company Name: PhoneNo.:� <br /> Site Address: K,�—Xp 4ca..,ay Ar-. Date of Testing/Servicing: 10/.jr /r3l _ <br /> 1':+,_,e 1 of 3 U:.nl <br /> �I�>nit�n in���>trm Crrtifiiati�ut <br />
The URL can be used to link to this page
Your browser does not support the video tag.