My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997-2002
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
16500
>
2300 - Underground Storage Tank Program
>
PR0231554
>
COMPLIANCE INFO_1997-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2021 4:00:13 PM
Creation date
6/3/2020 9:50:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-2002
RECORD_ID
PR0231554
PE
2361
FACILITY_ID
FA0005678
FACILITY_NAME
LATHROP SHELL
STREET_NUMBER
16500
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
LATHROP
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
16500 S HARLAN RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231554_16500 S HARLAN_1997-2002.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
482
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1111011111 M <br /> INDIVIDLW TANK INFORMATION ANEMEST RESULTS <br /> TEST DATE:01/08/01 8900 SHOAL CREEK, BUILDING 200 WORK ORDER NUMBER2215063 <br /> CLIENT:TOSCO MARKETING AUSTIN,TEXAS 78757(512)451-6334 SITE:BP 1-1195/CC#2611195 <br /> Tank ID: 3 Tank manifolded: NO Bottom to top fill in inches: <br /> Product: REG UNLEAD Vent manifolded: YES Bottom to grade in inches: <br /> Capacity in gallons: 11,849 Vapor recovery manifolded: yES Fill pipe length in inches: <br /> Diameter in inches: 120.00 Overfill protection:yES Fill pipe diameter in inches: 4.0 <br /> Length in inches: 352 Overspill protection: YES Stage I vapor recovery: DUAL <br /> Material: DW FIBERG Installed: ATG Stage II vapor recovery: ASSIST <br /> CP installed on: <br /> COMMENTS <br /> Dipped Water Level: New/passed Failed/replaced New/passed Failed/replaced <br /> Dipped Product Level: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> Probe Water Level: Make: RED JACKET <br /> Ingress Detected: Water Bubble Ullage Model: Fx1vS/N: 10596-9489 <br /> Test time: Open time in sec: 2.00 <br /> Inclinometer reading: <br /> VacuTect Test Type: NOT Holding psi: is <br /> Resiliency cc: 100 NOT <br /> VacuTect Probe Entry Point: TESTED Test leak rate ml/m: 189.0 TESTED <br /> Pressure Set Point: Metering psi: 10 <br /> Tank water level in inches: Calib. leak in gph: 3.00 <br /> Water table depth in inches: Results: PASS <br /> Determined by(method): <br /> Result: <br /> COMMENTS <br /> COMMENTS <br /> �x <br /> Material: DW FIBERG <br /> Diameter(in): 2.0 <br /> Length (ft): 70.0 <br /> Test psi: <br /> Bleedback cc: <br /> Test time (min): NOT NOT NOT NOT <br /> Start time: TESTED TESTED TESTED TESTED <br /> End time: <br /> Final gph: <br /> Result: <br /> Pump type: PRESSURE <br /> Pump make: FE PETRO <br /> COMMENTS Impact Valves Operational:yES <br /> Printed 01 A 0/2001 08:51 <br />
The URL can be used to link to this page
Your browser does not support the video tag.