Laserfiche WebLink
LUL/ULC LISTED <br />SECONDARY i ' <br />TEE 900 ELBOW 450 ELBOW SLEEVE COUPLING <br />4 <br />y'Splp� k",yc ! �P ti• i ��YTv• <br />c A <br />TERMINATION• <br />WITH 3/4" NPT <br />Sizes available for Termination Concentric Reducers, <br />with and without tap: 3"x 2", 4"x 3", *6"x 4". <br />SIZES <br />SIZES AVAILABLE <br />Belled Side Outlet <br />Threaded Side Outleterna <br />NPT Intl Threadsl2l <br />3"x2" <br />3"x1" <br />4" x 2" <br />3" x 11/4" <br />4"x3" <br />3"x1'/i, <br />7 <br />4"x1" <br />3 <br />4" x 11/4" <br />21/2 <br />_4"_x 1 th" <br />Size ., <br />A <br />B <br />C <br />114 <br />D <br />E .. <br />F; <br />3" <br />6 <br />7 <br />at 1500 F <br />3 <br />21/2 <br />21/2 <br />4" <br />71/2 <br />8 <br />14 <br />3 <br />3 <br />21/2 <br />6"* <br />8 <br />9 <br />16 <br />4 <br />4 <br />1 3 <br />PRESSURE RATINGS <br />Size <br />prig at , <br />150-F ? ' <br />3" <br />90 <br />4" <br />80 <br />6"* <br />(4) <br />SADDLES <br />TERMINATION <br />CONCENTRIC REDUCER <br />F <br />D <br />1 1 Q <br />L T <br />x:. <br />E� <br />Bending Properties of RED THREAD 11 Pipe <br />- <br />Minimum <br />Nominal <br />Sending Radiu•13), <br />Pipe Size <br />761 F/24e c <br />at 750 F <br />Tensile Strength —Axial <br />50 ft. <br />2" <br />15.2 m <br />at 1500 F <br />80 f t <br />3„ <br />24.4 m <br />Compressive Strength — Axial at 750 F <br />100 fL <br />4" <br />30.5 m 71 <br />H <br />TYPICAL PHYSICAL'POPE14TIES(6a°'; <br />" r Property ,'', .r <br />Value <br />Value <br />Test Method <br />at 750 F <br />Tensile Strength —Axial <br />11,900 psi <br />82.05 MPa <br />ASTM D-2105 <br />at 1500 F <br />9,300 psi <br />64.12 MPa <br />Compressive Strength — Axial at 750 F <br />22,700 psi <br />156.51 MPa <br />ASTM D-695 <br />at 750 F <br />Modulus of Elasticity in Tension at 1500 F <br />1.92 x 106 psi <br />1.70 x 106 psi <br />1.32 x 104 MPa <br />1.17 x 104 MPa <br />ASTM D-2105 <br />Ultimate Hoop Tensile Strength at Burst <br />Average at 750 F <br />44,000 psi <br />303.37 MPa <br />ASTM D-1599 <br />Long Term Hoop Strength at 75* F <br />9,140 psi <br />63.02 MPa <br />ASTM D-2992 <br />Cyclic Pressure (150 x 106 cycles) at 1.500 F <br />8,020 psi <br />55.30 MPa <br />Procedure A <br />Thermal Expansion Axial <br />2" 3" 4" pipe <br />1.09 x 10-5 in./in./0F <br />1.96 x 10-5 mm/mm/OC <br />AOSI-TM16-3 <br />Thermal Conductivity <br />2" 3" 4" pipe <br />2.9 BTU/(ft.2)(hr.)(OF/in.) <br />0.42 W/(m)(OK) <br />AOSI-TM16-15 <br />Specific Gravity <br />1.85 <br />1.85 <br />ASTM D-792 <br />Flow Factor <br />Hazen -Williams Coefficient <br />I-- <br />150 <br />150 <br />AOSI <br />(1) A 3"x 2" reducer bushing which is (2) Threaded connections (3) Sharper bends should be eliminated (4) Data not available at time of (6) Pipe is manulactured in compliance <br />not UL/ULC Listed is available for must be made with a to avoid stress concentration which printing. with ASTM 0-2996. Refer to general <br />use with the 4"x 3" termination flexible connector. would result in premature pipe failure specification sheet in catalog for the <br />concentric reducer. under pressure conditions. (5) Tests run on pipe samples. D-2996 designation code. <br />7 <br />