My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997-2002
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
16500
>
2300 - Underground Storage Tank Program
>
PR0231554
>
COMPLIANCE INFO_1997-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2021 4:00:13 PM
Creation date
6/3/2020 9:50:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-2002
RECORD_ID
PR0231554
PE
2361
FACILITY_ID
FA0005678
FACILITY_NAME
LATHROP SHELL
STREET_NUMBER
16500
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
LATHROP
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
16500 S HARLAN RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231554_16500 S HARLAN_1997-2002.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
482
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 D1 DMA `I q-r, <br /> UNIFIED PROGRAM CONSOLIDATED FORM `�//b/02- <br /> TANKS <br /> UNDERGROUND STORAGE TANKS-TANK PAGE 1 <br /> (twin pages per tank) <br /> Page of_ <br /> TYPE OF ACTION [:11. NEW SITE PERMIT ❑4. AMENDED PERMIT ®5. CHANGE OF INFORMATION) ❑6. TEMPORARY SITE CLOSURE <br /> (Check one item only) ❑7. PERMANENTLY CLOSED ON SITE <br /> ❑3. RENEWAL PERMIT [:18. TANK REMOVED 430 <br /> (Sped reason-for loco/use only) (Specify change-for local use only) <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) 3 FACILITY ID# 1 <br /> Tosco Corporation#2611195/11195/30225 <br /> LOCATION WITHIN SITE(Optional) 431 <br /> L TANK DESCRIPTION (A scaled plot plan with the location ojthe UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# 432 TANK MA FACTURER 433 COMPARTMENTALIZED TANK E] YesNo 434 <br /> -r� o5pg�3 ( P ( If[]Yes L;,complete one page for each comp n m <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> Mq la O <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> II.TANK CONTENTS <br /> �/ TANK USE 439 ��������,,��,,//,,//// PETROLEUM TYPE 440 <br /> . MOTOR VEHICLE FUEL a. REGULAR UNLEADED ❑ 2. LEADED ❑ 5. JET FUEL <br /> (Ijm Irked,complete Petroleum Type) 1b. PREMIUM UNLEADED ❑ 3. DIESEL ❑ 6. AVIATION FUEL <br /> ❑ 2. NON-FUEL PETROLEUM ❑lc. MIDGRADE UNLEADED ❑ 4. GASOHOL ❑99. OTHER <br /> ❑3. CHEMICAL PRODUCT <br /> ❑ 4. HAZARDOUS WASTE(Includes COMMON NAME(from Hazardous Materials Inventory page) 441 CAS#(from Hazardous Materials Inventory page) 442 <br /> Used Oil) <br /> ❑95. XERXES <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK 1:11, SINGLE WALL ❑ 3. SINGLE WALL WITH ❑ 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> 2. DOUBLE WALL EXTERIOR MEMBRANE LINER ❑95. XERXES <br /> (Check one item only) ❑ 4. SINGLE WALL IN A VAULT <br /> ❑99 OTHER <br /> TANK MATERIAL-primary tank ❑1. BARE STEEL P511FIBERGLASS/PLASTIC [-]5. CONCRETE ❑95. XERXES 444 <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPATIBLE W/100%METHANOL ❑99. OTHER <br /> REINFORCED PLASTIC FRP <br /> TANK MATERIAL-secondary tank ❑1 BARE STEEL FIBERGLASS/PLASTIC ❑8. FRP COMPATIBLE W/100%METHANOL ❑95. XERXES 445 <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑9. FRP NON-CORRODIBLE JACKET ❑99. OTHER <br /> REINFORCED PLASTIC(FRP) ❑10. COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING ❑ 1. RUBBER LINEDDATE INSTALLED 447 <br /> OR COATING 3. EPDXY LINING 5 GLASS LINING 95. XERXES 446 <br /> ❑2. ALKYD LINING ❑4. PHENOLIC LINING .UNLINED ❑99. OTHER <br /> Check one item only) For local use onl <br /> OTHER CORROSION ❑L MANUFACTURED 3. FIBERGLASS REINFORCED PLASTIC ❑95. XERXES 448 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE CATHODIC <br /> 4. IMPRESSED CURRENT ❑99. OTHER <br /> PROTECTION <br /> (Check one item only) ❑2 SACRIFICIAL.ANODE (For local use only) <br /> SPILL AND OVERFILL YEAR 1450 TYPE(For local use only) 451 OVERFILL PROTECTION EQUIX'ILL <br /> :YEAR INSTALLED n,� 452 <br /> (Check all that apply) 1. SPILL CONTAINMENT ❑1. ALARM TUBE SHUT OFF VALVE <br /> DROP TUBE ❑2. BALL FLOAT ❑4. EXEMPT <br /> STRIKER PLATE <br /> IV. TANK LEAK DETECTION (A description ojthe monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK(Check all that apply): 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER(Check one item onlv): 454 <br /> F-11, VISUAL(EXPOSED PORTION ONLY) ❑5. MANUAL TANK GAUGING(MTG) ❑L VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2. AUTOMATIC TANK GAUGING(ATG) ❑6. VADOSE ZONE 6122. CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3. CONTINUOUS ATG ❑7. GROUNDWATER 3. MANUAL MONITORING <br /> ❑4. STATISTICAL INVENTORY RECONCILIATION(SIR)+ ❑8. TANK TESTING <br /> BIENNIAL TANK TESTING ❑99. OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> gallons <br /> �. Yes No <br /> ._ <br /> UPCF(1/99 revised) Formerly SWRCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.