My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003-2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
16500
>
2300 - Underground Storage Tank Program
>
PR0231554
>
COMPLIANCE INFO_2003-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2021 2:05:37 PM
Creation date
6/3/2020 9:50:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2010
RECORD_ID
PR0231554
PE
2361
FACILITY_ID
FA0005678
FACILITY_NAME
LATHROP SHELL
STREET_NUMBER
16500
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
LATHROP
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
16500 S HARLAN RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231554_16500 S HARLAN_2003-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
359
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br /> Page 2 of 8 <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: ❑Tank Manufacturer I] Industry Standard ❑Professional Engineer <br /> ❑ Other(Specify) <br /> Test Method Used: Pressure El Vacuum ❑Hydrostatic <br /> ❑ Other(Specify) <br /> Test Equipment Used:Vacuum Gauge Equipment Resolution: 0-30 Hg <br /> Tank# 1 Tank# 2 Tank # Tank# <br /> Is Tank Exempt From Testing? ❑ Yes ® No ❑ Yes ® No ❑ Yes ❑ No ❑ Yes ❑ No <br /> Tank Capacity: 11849 11849 <br /> Tank Material: Fiberglass Fiberglass <br /> Tank Manufacturer: Unknown Unknown <br /> Product Stored: 87 91 <br /> Wait time between applying <br /> pressure/vacuum/water and starting 10 min 10 min <br /> test: <br /> Test Start Time: 10:15 AM 10:20 AM <br /> Initial Reading(Ri): -7 Hg -7 Hg <br /> Test End Time: 11:15 AM 11:20 AM <br /> Final Reading(RF): -7 Hg -7 Hg <br /> Test Duration: 1 Hr 1 Hr <br /> Change in Reading(RF-Ri): O Hg O Hg <br /> Pass/Fail Threshold or Criteria: <br /> `f`eg Resuk .®PassL3 Fail 0 Pass 0,11i L]'Pass' L1 Fait LJ Pass L3 Fall <br /> Was sensor removed for testing? ❑O Yes ❑ No ❑ NA ©Yes ❑ No ❑ NA ❑Yes ❑ No ❑ NA ❑Yes ❑ No ❑ NA <br /> Was sensor properly replaced after ®Yes ❑ No ❑ NA Il)Yes ❑ No ❑ NA ❑Yes ❑ No ❑ NA ❑Yes ❑ No ❑ NA <br /> testing? <br /> Comments—(include information on repairs made prior to testing,and recommended follow-up for failed tests) <br /> ' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary containment, <br /> such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment testing. <br /> {California Code of Regulations,Title 23,Section 2637(a)(6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.