My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HOSPITAL
>
500
>
2300 - Underground Storage Tank Program
>
PR0231614
>
COMPLIANCE INFO_2006-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/19/2021 1:21:17 PM
Creation date
6/3/2020 9:50:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2012
RECORD_ID
PR0231614
PE
2361
FACILITY_ID
FA0000086
FACILITY_NAME
San Joaquin General Hospital
STREET_NUMBER
500
Direction
W
STREET_NAME
HOSPITAL
STREET_TYPE
Rd
City
French Camp
Zip
95231
CURRENT_STATUS
01
SITE_LOCATION
500 W Hospital Rd
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231614_500 W HOSPITAL_2006-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
368
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> Facilit <br /> Name: San Joaquin General Hospital Address: 500 W. Hospital Rd, French Camp Daeection Aug 24, 2012 <br /> FacilityTitle: e' <br /> Contact: Jesse Escotto/Jesse Berumen Engineer/contractor 257/7125931(c) <br /> Inspection XRoutine XMonitoring System Certification ❑Installation ❑Complaint—ID#: ❑Other: <br /> Type: <br /> (Authority HSC 25289) Jesse Berumen contractor <br /> Consent for: Xlnspection XSampling XPhotos Granted by: Title: <br /> Monitoring OPW ik Gau Piping Overfill <br /> Panel: g System: XPressurized ❑Suction 11Gravity Prevention: XMechanical ❑Audible/visual <br /> touch Tan <br /> UST 6 <br /> ---Product--- -------------- -------------- --------------------------------DSL---- --------------------------- ----------- <br /> Designated Jesse Berumen ICC Exp, 061814 Violations: 11M1-Release Detection F1 M2-Release Prevention ❑M3—Both <br /> Operator: Date: <br /> On Site Service ICC Exp. Manufacturer's Dew <br /> Technician: Date: Trainin 3 <br /> VIOLATIONS <br /> # Cl C2 M I Code Section HSC=California Health and Safety Code;CCR=California Code of Regulations <br /> C1=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> 101 HSC 25284 No permit to operate <br /> 102 HSC 25404.5 Annual operating fees not paid <br /> 103 HSC 25284(a)(3) No written agreement between the person that the operating permit was issued to and the tank operator to <br /> monitor the tanks stem <br /> 104 X HSC 25292.2 Current financial responsibility documents not on file with the Environmental Health Department(EHD) <br /> 105 CCR 2711 Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form) <br /> 106 CCR 2632(b) Monitoring Program(Monitoring&Response Plans)is not current or approved by the EHD <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or fails to completely show where monitoring is performed <br /> 108 CCR 2637 Secondary containment:(a)test not performed;(e)test report not submitted within 30 days;(f)test notification <br /> not provided to the EHD at least 48 hours prior to conducting the test <br /> Monitoring equipment certification:(a)not performed annually;(d)test report not submitted within 30 days; <br /> 109 CCR 2638 (e)test notification not provided to the EHD at least 4hours prior to conducting an installation,repair, <br /> replacement,calibration,or certification <br /> 110 HSC 25291(f) Annual line leak detector test not performed (M1) <br /> 111 HSC 25284.2 Annual spill containment testing not performed <br /> 112 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present (M7) <br /> 113 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br /> 114 CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification <br /> 115 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br /> permit conditions <br /> 116 HSC 25292.5 Enhanced leak detection(ELD)testing not performed on a system located within 1000'of public well,or <br /> failures not repaired and retested <br /> 117 CCR 2661 Permit to repair UST system not obtained <br /> 118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br /> 119 HSC 25298(b) Permit to temporarily close UST system not obtained <br /> 120 HSC 25298(c) Permit to close UST system not obtained <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6'%years,written <br /> performance claims pertaining to release detection systems for 5 years,or records of repairs,linings,and <br /> 201 CCR 2712(b) upgrades for the life of the tank. Monitoring records include:(1)date and time of all monitoring or sampling; <br /> (2)monitoring equipment calibration and maintenance records;(3)results of any visual observations;(4) <br /> results of sample analysis performed a lab or in the field;(5)logs of all readings of gauges or other monitoring <br /> equipment, round water elevations,or other test results; 6 results of inventory readings and reconciliations <br /> 202 CCR 2712(i) Monitoring plan,response plan,and/or operating permit and all conditions not onsite <br /> Unauthorized release that:(c)did not escape secondary containment and cleaned up within eight hours (M7) <br /> 203 CCR 2650 was not recorded;(e)escaped secondary containment,not cleaned up after eight hours,or a sudden loss of <br /> product was not reported to the EHD within 24 hours <br /> Inspector I R15c ved By: Title: <br /> Thuy Tran (209) 468-8257 &�.' v�L <br /> EHD 23-02 Rev 04/19/12 Page 1 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.