Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.soclov.ora/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Facility name: Inspection date: <br /> San Joaquin General Hospital August 26, 2011 <br /> Facility address: UST#/ 6 <br /> 500 West Hospital Road, French Camp Product �DSL11' <br /> Facility contact: Title: Phone: <br /> Jesse Escotto Interim Facilities Mgr <br /> t � <br /> Moni ane: Piping system: Overfill prevention: Violations: <br /> I <br /> Tan V- 0ressurized�� uctionL]Gravity Mechanical M1-RDetect OM2-RPrevUM3-Both <br /> udible/visual <br /> Inspection type: Designated operator: ICC exp.date: <br /> Routine 19 Monitoring Certification DInstallation 00ther "James Payton 09/15/2012 <br /> On site Service Technician's name: D C exp.date: Manufactu s trail ling.:_ <br /> haakis c) <br /> # Code Section 0111-01 VIOLATIONS Qpt 1�- kSW:-!C 0q-1& 14 R <br /> HSC=CA Health&Safety Code; CCR=CA Code of Regulations;V=Violation; RV=Re eat Violation V <br /> 1 HSC 25284 No permit tooperate <br /> Secondary containment:(a)test not performed;(e)test report not submitted within 30 days;(f)test <br /> 2 CCR 2637 notification not provided to the E ironmental Health Department(EHD)at least 48 hours prior to <br /> 11 conductin the test 3l3 q <br /> 3 CCR 2711 Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form <br /> 4 HSC 25292.2 Current financial responsibility documents not on file with the EHD <br /> 5 '' CCR 2632(b) Monitoring Program(Monitoring&Response Plans is not current or 6pproved by the EHD <br /> 6 CCR 2712(i) Monitoring Ian,response plan,and/oroperating permit and all conditions not onsite <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6 Y2 (MI), <br /> years,written performance claims pertaining to release detection systems for 5 years,or records of <br /> repairs, linings,and upgrades for the life of the tank. Monitoring records include:(1)date and time of <br /> 7 CCR 2712(b) all monitoring or sampling;(2)monitoring equipment calibration and maintenance records;(3)results <br /> of any visual observations;(4)results of sample analysis performed a lab or in the field;(5)logs of all <br /> readings of gauges or other monitoring equipment,ground water elevations,or other test results;(6) <br /> results of inventory readings and reconciliations <br /> 8 'i CCR 2643(d) Daily monitoring of suction piping(pre-January1, 1984 not performed (Mt) <br /> 9 ;, HSC 25292.1 UST system is not operated to prevent unauthorized release, including spills and overfills <br /> 10 `' CCR 2632 c 2 Monitoringsystem is not resent in the interstitials ace of a double walled UST (M1) <br /> 11 CCR 2630 d UST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity(mi) <br /> 12 ;' HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary (Ml) <br /> containment <br /> 13 CCR 2636(f)(1) Failed to maintain a continuous monitoring system for underground piping&UDCs that activates (M1) <br /> i <br /> an audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br /> I' 14 CCR 2631 a Primary containment is not product tight <br /> 15 `i HSC 25291(a)(2) Secondary containment for UST system is not tight <br /> 16 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sum <br /> ` 17 CCR 2636(f)(2) Line leak detectors not installed or failed to detect a 3-gallon per hour leak at 10 psi (M1) <br /> 18 CCR 2635(b)(1) Spill container failed to contain a minimum capacity of five gallons,or failed to provide a means (M2) <br /> to keep the spill container empty <br /> ' 19 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements in this section (Mz <br /> 20 CCR 2636(a) Failed to have secondary containment for piping(includes conventional suction piping) (1%1112 <br /> 21 HSC 25291 a Water in 21 containment not removed,analyzed&properly disposed of <br /> Unauthorized release that:(c)did not escape secondary containment and cleaned up within eight (M1) <br /> 22 CCR 2650 hours was not recorded;(e)escaped secondary containment, not cleaned up after eight hours,or a <br /> sudden loss of product was not reported to the EHD within 24 hours <br /> j 23a CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br /> 23b CCR 2715(b) Designated operator did not possess a current ICC UST System Operator certification <br /> EHD ins e tor: C\=� Received by: 'le: <br /> .a <br /> EHD 23-02-002 REV 07/12/11 Pagel k ` UST INSPECTION REPORT <br />