My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HOSPITAL
>
500
>
2300 - Underground Storage Tank Program
>
PR0231614
>
COMPLIANCE INFO_2006-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/19/2021 1:21:17 PM
Creation date
6/3/2020 9:50:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2012
RECORD_ID
PR0231614
PE
2361
FACILITY_ID
FA0000086
FACILITY_NAME
San Joaquin General Hospital
STREET_NUMBER
500
Direction
W
STREET_NAME
HOSPITAL
STREET_TYPE
Rd
City
French Camp
Zip
95231
CURRENT_STATUS
01
SITE_LOCATION
500 W Hospital Rd
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231614_500 W HOSPITAL_2006-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
368
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LEADING THEY IN FUELING INNOVATION WORLkIDE <br /> Compliance Probe Specifications <br /> ♦ The system is certified to meet or exceed U.S. Environmental Type:Magnetostrictive/Float <br /> Protection Agency's performance standards for 0.1 gph(0.38 Material:Stainless Steel Body,Aluminum Cap <br /> Iph)volumetric tank tightness testing and 0.2 gph(0.76 Iph) Location:Hazardous,Class 1,Division 1, Group D <br /> monthly monitoring <br /> Temperature:5 RTDs <br /> ♦ Supports ALD with SiteSentinel®ATG family and supports SLD Temperature Range:-400 to 1400 F(400 to 600 C) <br /> with SiteSentinel®iSite" <br /> Data Cable: 1000'(300 m)Belden 88760 <br /> Magnetostrictive Probe Data 500'(150 m)max.Belden 88761 <br /> ♦ Measures product level changes to a resolution of <br /> 0.0005"(0.0127 mm) Probe Length <br /> Part No. Description <br /> ♦ Measures product temperature changes to 30-6053 53" crap cm) <br /> a resolution of 0.0010 F(0.00050 C) <br /> 30-BO69 69"(175 cm) <br /> ♦ Measures water level changes to a resolution of 30-BO77 77"(196 cm) <br /> 0.01"(0.254 mm) 30-BO89 89"(226 cm) <br /> ♦ Linearity over the entire probe length is t 0.04"(1 mm) 30-B101 101"(257 cm) <br /> Leak Test Performance 30-8105 105"(267 cm) <br /> ♦ 3rd party certified to meet US EPA Leak Detection 30-B113 113"(287 cm) <br /> requirements(Static and SLD)in tanks up to 20,000 gallons 30-8125 125"(317 cm) <br /> (76,000 liters) 30-B137 137"(350 cm) <br /> ♦ 0.2 gph(0.76 Iph)Static Leak Test:98.18%Pd, 1.82%Pfa 30-8149 149"(376 cm) <br /> ♦ 0.1 gph(0.38 Iph)Static Leak Test:96.5%Pd,3.5%Pfa Probe Float Kits <br /> ♦ 0.2 gph(0.76 Iph)Automatic Leak Detection(ALD) Part No. Description <br /> ♦ 0.1 gph(0.38 Iph)Automatic Leak Detection(ALD) 30-1509-02 2"(5.1 cm)Gas/Water Nitrophyl Float Kit <br /> ♦ 3rd party certified to meet US EPA Leak Detection 30-1509-01 2"(5.1 cm)Diesel/Water Nitrophyl Float Kit <br /> requirements(SLD)in tanks up to 35,000 gallons 30-3232 2"(5.1 cm)Density Measurement Kit <br /> (132,475 liters) 30-1508-02 4"(10.2 cm)Gas/Water Nitrophyl Float Kit <br /> ♦ 0.2 gph(0.76]ph)Continuous Leak Test(SLD),99.1%Pd, 30-1508-01 4"(10.2 cm)Diesel/Water Nitrophyl Float Kit <br /> 0.9%Pfa Certified Probe 35,000 Gallon Tank(132,475 liters) 4"Float Kit required for SLD feature <br /> Stainless steel floats available upon request <br /> Note: No leak testing available with stainless steel floats <br /> GROUND LEVEL GROUND LEVEL <br /> 20 in. _20 in. <br /> 6 in.(15 cm) 6 in.(15 cm) <br /> +minimum ^(50 cm)~ Standard Riser t minimum (50 )�IGHT <br /> Standard Riser <br /> 4 in.(10 cm)inside diameter 4 in.(10 cm)inside diameter <br /> 13 in.�(33 cm) 13 in.(33 cm) <br /> 1 li MANHOLE H <br /> 1 i7 TANKPROBE PR E <br /> DIAM T R DIAMETEOBE E RLENGTH LENGTH <br /> - I <br /> i <br /> TANK DIAMETER+MANHOLE HEIGHT'+3 in.(8 cm)Minim�=PROBE LENGTH TANK DIAMETER+MANHOLE HEIGHT'+3 in.(8 cm)Minimum=PROBE LENGTH <br /> (Top of Tank to Top of Manhole Cover) '(Top of Tank to Top of Manhole Cover) <br /> OPW Fuel Management Systems <br />
The URL can be used to link to this page
Your browser does not support the video tag.