Laserfiche WebLink
02-25-93 15,34 FROM MEL&KIDES <br />INC- ID <br />2943 2046 <br />Cirnensiorns in inches: <br />ffw �_ �O_INC_ <br />Manttoided with Tank Number(s): <br />None <br />THE ECOLOr3Y F-ROFESSIONAL,S <br />N/A <br />P_ 3 <br />INDIVIDUAL TANK/UNE TIGHTNESS TEST REPORT <br />November 3, 1992 <br />Customer Site <br />Mel Borides M B P (C F N) CARD LOCK <br />Attn: Nick Borides 983 MOFFET <br />2191 Navy Drive MANTECA, CA 95206 <br />Stockton, GA 95246 Service Agreement # JB -5027 <br />(209) 943-2011 <br />Test Specifics <br />Tank: 02 of 4 <br />Product: UNLEADED PREMIUM <br />Capac'sty in gai"scl=;s: <br />4,000 <br />Cirnensiorns in inches: <br />75 x 210 x 0 <br />Manttoided with Tank Number(s): <br />None <br />Tank Isolated from Manifold: <br />N/A <br />Pump Type: <br />SUCTION <br />Tank Material: <br />Steel <br />Fuel I vol in Inches at Start of Test. <br />53.500 <br />l..-avel _ 1 .Nater in inches at Tost Start: <br />L.000 <br />Percentage ruii: <br />90.29 <br />Fuel Temperature (cF): <br />62,0 <br />Specific Gravity'. <br />0.784 <br />Surface Cover: <br />CEMENT <br />Diameter of Fi;! Pipe(s) in inches: Fill: 3.040 <br />Vent; 1.500 <br />Other: 0.000 <br />Other:O'mo <br />Depth to Water Table in inches: <br />0.000 <br />'rank Location: :MST NORTH OF TANK ONE, <br />Tinting Procedures. <br />Test Conclusions <br />Liquid Portion: <br />Leak Rate (gph): <br />Test Date: <br />Test Number: <br />Ullage Portion: <br />Test Number: <br />Line: <br />Leak Rate (gph) <br />Test Number: <br />Leak Detector: <br />Test Number: <br />Pass <br />0.001 Outgoing <br />10131/92 <br />21031CJH02T <br />"2hDCJHA2U <br />21102CJH03L <br />(Not Tested) <br />Facility Inspection Report: No <br />Site Comment: <br />The Nairne! Fire Pnu'vCto.- Act Code. NEPA 329, states a volume change of lass than 0.05 gallons per hour qualifies a tank to be considered ■tight' <br />The ° z r r. ,,mss boon CFRTIFiED by an Indbraenr;ent testing laboratory to meet E.P.A, specifications for testing underground storage tanks under <br />(Final fieport Ma 1:Y9C) The results era vend for the tested portion of ilia tank. <br />Allv".--' " , - O:'nforancea tram electrunio car other measurements. Our tests are pertrxrnod in accordance with standard; accepted In the <br />lnd ustt, <br />please contact ProEoo's regiona; otftca at 51 E. Campbell Avenue, Suite 110A, Campbell, CA 95W8 <br />1 @#e-Prr_„ V '405)8066-44441 Fax(408) 370.3155 <br />y FroEco Inc. Copyright 1992, 1991, 1990, 1987. Revision: RPTFLC2 <br />t .. , <br />■ t III l;J,, U?ii -I ZD11 <br />