My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2001-2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MOFFAT
>
983
>
2300 - Underground Storage Tank Program
>
PR0231691
>
COMPLIANCE INFO_2001-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2023 4:56:44 PM
Creation date
6/3/2020 9:50:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001-2009
RECORD_ID
PR0231691
PE
2361
FACILITY_ID
FA0003593
FACILITY_NAME
Nella Oil #487
STREET_NUMBER
983
STREET_NAME
MOFFAT
STREET_TYPE
Blvd
City
Manteca
Zip
95336
APN
221-15-06
CURRENT_STATUS
01
SITE_LOCATION
983 Moffat Blvd
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231691_983 MOFFAT_2001-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
396
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IFIED PROGRAM CONSOLIDATED FOR TANK: TA0507942 <br /> AM 6 PR#: PR0231691 <br /> UNDERGROUND STORAGE TANKS -TAN G <br /> j .,jjDFAC#: FA000359j3 <br /> wo pages per tank) <br /> Page 6 of 7 <br /> TYPE OF ACTION ❑ 1 NEW SITE PERMIT ❑ 4 AMENDED PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Check only itemonly) Rrr+ •,,,q. =°(I e 't+"„+)",f*a°IR!I9!'ls9t+i 144 <br /> =4; ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑3 RENEWAL PERMITNBEEMEMEW ❑8 TANK REMOVED 430 <br /> BUSINESS NAME(Same az FACILITY NAME orDBA-Doing Business As) <br /> FACILITY ID: PR#: I <br /> OLYMPIAN 3 FA0003593 PR0231691 <br /> LOCATION WITHIN SITE(Optional) 983 MOFFAT BLVD,MANTECA 431 <br /> PHONE <br /> I.TANK DESCRIPTION(A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# Tank#: 7 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK <br /> ❑Yes XNo 434 <br /> TA0507942 MODERN WELDING Ir='Yea",c%Mleteonepagefo mcbemparment. <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 6/1/1998 12,000 <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> II.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> ® I.MOTOR VEHICLE FUEL ❑ 1 a.REGULAR UNLEADED ❑ 2.LEADED ❑ 5.JET FUEL <br /> (If marked complete Petroleum Type) ❑ Ib.PREMIUM UNLEADED ® 3.DIESEL ❑ 6.AVIATION FUEL <br /> ❑2.NON-FUEL PETROLEUM ❑ 1c.MIDGRADE UNLEADED ❑ 4.GASOHOL ❑ 99.OTHER <br /> ❑ 3.CHEMICAL PRODUCT COMMON NAME(fran Hazardous Materials Invent CAS# from Hazardous Materials Invent page) <br /> ❑4.HAZARDOUS WASTE Inventory oral ( Inventory g) 4az <br /> (Mucks Used Oil) <br /> ❑ 95.UNKNOWN <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL ❑ 3.SINGLE WALL WITH ❑ 5.SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one item only) EXTERIOR MEMBRANE LINER ❑ 95.UNKNOWN <br /> ® 2.DOUBLE WALL ❑ 4.SINGLE WALL IN VAULT ❑ 99.OTHER <br /> TANK MATERIAL-primary tank ❑ 1.BARE STEEL ❑ FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 444 <br /> (Check one item only) ❑ 2.STAINLESS STEEL ® STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 99.OTHER <br /> TANK MATERIAL-secondary tank ❑ 1.BARE STEEL ❑ 3.FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 445 <br /> (Check one item only) ❑2.STAINLESS STEEL �4.STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 10.COATED STEEL ❑ 99.OTHER <br /> ❑ 5.CONCRETE <br /> TANK INTERIOR LINING ❑ 1.RUBBER LINED ❑ 3.EPDXY LINING ❑ 5.GLASS LINING ❑95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING <br /> (Check one item only) ❑ 2 ALKYD LINING ❑ 4 PHENOLIC LINING ® 6 UNLINED ❑ 99.OTHER <br /> (Far local use only) <br /> OTHER CORROSION ❑ 1 MANUFACTURING CATHODIC ® 3 FIBERGLASS REINFORCED PLASTIC ❑ 95 UNKNOWN 448 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE PROTECTION <br /> (Check oe item only) ❑ 4 IMPRESSED CURRENT E] 99 OTHER <br /> ❑ 2 SACRIFICIAL ANODE (For local use only) <br /> SPILL AND OVERFILL YEAR INSTALLE450 TYPE(local use only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> �4 I SPILL CONTAINMENT 1,998.00 <br /> (Check all that apply) [�, ❑ 1 ALARM K 3 FILL TUBE SHUT OFF VAL` <br /> �;SL.2 DROP TUBE 2 BALL 417 q [ ] 4 EXEMPT <br /> STRIKER PLATE LOAT <br /> IV.TANK LEAK DETECTION(A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK(Check all that apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> ❑ I VISUAL(EXPOSED PORTION ONLY) ❑ 5 MANUAL TANK GAUGING(MTG) (Chock we nem only) <br /> ❑ 2 AUTOMATIC TANK GAUGING(ATG) ❑ 6 VADOSE ZONE ❑ 1 VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑ 3 CONTINUOUS ATG ❑ 7 GROUNDWATER ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑ 8 TANK TESTING ❑3 MANUAL MONITORING <br /> (SIR)BIENNIAL TANK TESTING ❑ 99 OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> 0.00 gallons El Yes E] No <br /> UPCF(12/99 revised) <br />
The URL can be used to link to this page
Your browser does not support the video tag.