My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2001-2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MOFFAT
>
983
>
2300 - Underground Storage Tank Program
>
PR0231691
>
COMPLIANCE INFO_2001-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2023 4:56:44 PM
Creation date
6/3/2020 9:50:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001-2009
RECORD_ID
PR0231691
PE
2361
FACILITY_ID
FA0003593
FACILITY_NAME
Nella Oil #487
STREET_NUMBER
983
STREET_NAME
MOFFAT
STREET_TYPE
Blvd
City
Manteca
Zip
95336
APN
221-15-06
CURRENT_STATUS
01
SITE_LOCATION
983 Moffat Blvd
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231691_983 MOFFAT_2001-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
396
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SY EM SET-UP REPORT Page 2) <br /> AUTO DIAL TIME GETUP: R3-232' END OF MESSAGE IN-TANK SETUP <br /> DISABLED - - - - - - - - - - - <br /> I; l :IT AUTO DIAL ALARM SETUP T 1 :87 <br /> DIAL ON DATE - - - - - - - - - - - - PRODUCT CODE I <br /> JUN 22, 2006 THERMAL i_OEFF : .000700 <br /> DIAL TIME : DISABLED D 1 :IT TANK DIAMETER 96.00 <br /> RECEIVER REPORTS: TANK PROFILE 4 PTS <br /> IN-TANK ALARMS FULL VOL 8000 <br /> ALL:LEAK ALARI^1 72.0 INCH VOL 6476 <br /> RECEIVER SETUP: ALL:HIGH WATER ALARM 48.0 INCH VOL 4037 <br /> RLL:OVERFILL ALARM 24.0 INCH VOL 1551 <br /> ALL:LOW PRODUCT ALARM <br /> D 1 :IT ALL:SUDDEN LOSS ALARM <br /> 0026 ALL:HIGH PRODUCT ALARM FLOAT SIZE: 4.0 IN. <br /> RCVR TYPE: COMPUTER ALL: INVALID FUEL LEVEL. WATER WAkNIIVG :.0 <br /> PORT NO: 3 ALL:PROBE OUT <br /> RETRY NO: 3 ALL:HIGH WATER WARNING HIGH WATER LIMIT: 3,0 <br /> RETRY DELAY: 3 ALL:DELIVERY NEEDED <br /> CONFIRMATION REPORT: ON ALL:MAX PRODUCT ALARM MAX OR LABEL VOL: 8000 <br /> ALL:GROSS TEST FAIL OVERFILL LIMIT 90% <br /> ALL:PERIODIC TEST FAIL 7200 <br /> ALL:ANNUAL TEST FAIL HIGH PRODUCT 95"0 <br /> ALL:PER TST NEEDED WRN 7600 <br /> ALL:ANN TST NEEDED WRN DELIVERY LIMIT 15% <br /> ALL:PER TST NEEDED ALM 1200 <br /> ALL:ANN TST NEEDED ALM LOW PRODUCT 400 <br /> ALL:TANK TEST ACTIVE LEA}; ALARM LIMIT: 99 <br /> ALL:NO CSLD IDLE TIME SUDDEN LOSS LIMIT: 25 <br /> ALL:TANK SIPHON BREAK <br /> ALL:CTANK TILT 0,00SLD INCR RATE WARN TANK <br /> 0.00 <br /> ALL:ACCU_CHART CAL WARN PROBE <br /> ALL:RECON WARNING <br /> ALL:RECON ALARM <br /> ALL:LOW TEMP WARNING SIPHON MANIFOLDED TANKS <br /> ALL:MISSING TICKET WARN TO: NONE <br /> ALL:GROSS FAIL LINE TNK LINE MANIFOLDED TANKS <br /> TO: NONE <br /> ALL:DELIVY DENSITY WARN <br /> LIQUID SENSOR ALMS LEAK MIN PERIODIC: 75% <br /> ALL:FUEL ALARM 6000 <br /> ALL:SENSOR OUT ALARM PERIODIC TEST TYPE <br /> ALL:SHORT ALARM STANDARD <br /> ALL:WATER ALARM PERIODIC TEST FAIL <br /> ALL:WATER OUT ALARM <br /> ALL:HIGH LIQUID ALARM ALr,RM DISABLED <br /> ALL:LOW LIQUID ALARM GROSS TEST FAIL <br /> ALL:LIGUID WARNING <br /> ALARM DISABLED <br /> RECEIVER ALARMS <br /> SERVICE REPORT WARN PER TEST AVERAGING: OFF <br /> ALARM CLEAR WARNING TANK TEST NOTIFY: OFF <br /> DELIVERY REPORT WRN <br /> NO DIAL TONE ALARM TNK TST SIPHON BREAKOFF <br /> SMARTSENSOR ALARMS MIN <br /> 5 DELIVERY DELA`! MIN <br /> ALL:SETUP DATA WARNING PUMP THRESHOLD 15 <br /> ALL:COMMUNICATION ALARM <br /> ALL:SENSOR FAULT ALARM <br /> ALL:FUEL WARNING, <br /> ALL:FUEL ALARM <br /> ALL:WATER WARNING <br /> ALL:WATER ALARM <br /> ALL:HIGH LIQUID WARNING <br /> ALL:HIGH LIQUID ALARM <br /> ALL:LOW LIQUID WARNING <br /> ALL:LOW LIQUID ALARM <br /> ALL:SENSOR FAULT WARN <br /> PMC ALARMS <br /> VP EMISSIONS WARN <br /> VP EMISSIONS FAIL <br /> VP PRESSURE WARN <br /> VP PRESSURE FAIL <br /> PMC SETUP FAIL <br /> PMC SENSOR FAULT <br /> ©2006 Walton Engineering,Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.