PE
2361
FACILITY_ID
FA0003593
FACILITY_NAME
Nella Oil #487
STREET_NUMBER
983
STREET_NAME
MOFFAT
STREET_TYPE
Blvd
City
Manteca
Zip
95336
APN
221-15-06
CURRENT_STATUS
01
SITE_LOCATION
983 Moffat Blvd
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231691_983 MOFFAT_2001-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
396
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDER DISPENSER CONTAINMENT INDC) TESTING <br />Test Method By: O Manufacturer • Industry Standard o Professional Engr o Other (see below) <br />Test Method Uses: O Pressure O vacuum • Hydrostatic o Other (see below) <br />Measuring Equipment Used: INCON TS -STS (Electronic Sump Test System) <br />Description Diso # 1/2 Diso # 314 DISK) # 5/6 DisD # 7/8 <br />UDC manufacturer <br />Total Containment <br />Total Containment <br />Total Containment <br />Total Containment <br />UDC material <br />Poly <br />Poly <br />Poly <br />Poly <br />UDC depth (inches) <br />38 <br />38 <br />38 <br />38 <br />Height from UDC bottom to highest <br />piping penetration <br />6 <br />10 <br />14 <br />13 <br />Height from UDC bottom to lowest <br />electrical penetration <br />10 <br />6 <br />10 <br />10 <br />Condition of UDC prior to testing <br />Dry <br />0:15 <br />Dry <br />Dry <br />Portion of UDC tested <br />Entire <br />Pass/Fail threshold (±0.0020 inches / i Hr.) <br />Entire <br />Entire <br />Type of shut -down present <br />Sensor <br />Sensor <br />Sensor <br />Sensor <br />Was sensor removed for testing? <br />Yes <br />Yes <br />Yes <br />Was sensor properly replaced after testing? <br />Yes <br />Yes <br />Yes <br />Depth of water level from UDC bottom (in.) <br />12 <br />16 <br />15 <br />Wait time for water level to stabilize (hr:min) <br />0:05 <br />0:05 <br />0:05 <br />Test start time <br />10:31 AM <br />11:14 AM <br />11:50 AM <br />Initial Probe Reading <br />2.2248 <br />3.8603 <br />2.6302 <br />Test end time <br />10:46 AM <br />11:29 AM <br />12:05 PM <br />Final Probe Reading <br />2.2248 <br />3.8602 <br />2.6307 <br />Test duration (hr:min) <br />0:15 <br />0:15 <br />0:15 <br />Change in water level (t 0.0000 inches) <br />0.0000 <br />-0.0001 <br />0.0005 <br />Pass/Fail threshold (±0.0020 inches / i Hr.) <br />0.0020 <br />0.0020 <br />0.0020 <br />TEST RESULT <br />PASS <br />PASS <br />PASS <br />Comments: <br />This is a Re -test of the UDC's 1, 3 and 4 only. <br />0 2006 Walton Engineering, Inc. <br />