COMPLIANCE INFO_2001-2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MOFFAT
>
983
>
2300 - Underground Storage Tank Program
>
PR0231691
>
COMPLIANCE INFO_2001-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2023 4:56:44 PM
Creation date
6/3/2020 9:50:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001-2009
RECORD_ID
PR0231691
PE
2361
FACILITY_ID
FA0003593
FACILITY_NAME
Nella Oil #487
STREET_NUMBER
983
STREET_NAME
MOFFAT
STREET_TYPE
Blvd
City
Manteca
Zip
95336
APN
221-15-06
CURRENT_STATUS
01
SITE_LOCATION
983 Moffat Blvd
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231691_983 MOFFAT_2001-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
396
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITCV.ING SYSTEM CERTIF*ATION <br />MAKE / MODEL OF MONITORING SYSTEM: Veeder-Root TLS -350 <br />CERTIFICATION /TEST DATE: March 26, 2009 <br />Al. FACILITY <br />Name Olympian # 487 <br />Address 983 Moffat Blvd., Manteca, CA 95336 <br />Phone # 530-885-0401 <br />Contact Amanda Appelt <br />A2. OWNER <br />Name Nella Oil Company, LLC <br />Address 2360 Lindbergh Street, Auburn, CA 95602 <br />Phone # 530-885-0401 <br />Contact Amanda Appelt <br />A3. C U P A <br />❑ In -Tank Gauging Probe <br />A4. TESTING CONTRACTOR <br />Name <br />San Joaquin County Environmental Health <br />■ Piping Sump / Trench Sensor(s) <br />Name <br />Walton Engineering, Inc. <br />Address <br />600 E. Main Street, Stockton, CA 95202 <br />Model: <br />Address <br />P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified <br />March 23, 2009 <br />❑ Other (specify equipment in Section E) <br />Lic # <br />617238 A, B, Haz <br />Inspector <br />Muniappa Naidu <br />Tank Overfill / High -Level Sensor <br />Contact <br />Richard Walton <br />Phone # <br />209-468-3439 <br />Phone # <br />916-825-3203 <br />B. INVENTORY OF EQUIPMENT TESTED/CERTIFIED (Check the appropriate boxes to indicate equipment inspected/serviced) <br />131: TANKS <br />Tank #1 (Product): Gasoline - 87 <br />❑ In -Tank Gauging Probe <br />■ Annular Space or Vault Sensor <br />■ Piping Sump / Trench Sensor(s) <br />❑ Fill Sump Sensor(s) <br />❑ Mechanical Line Leak Detector <br />❑ Electronic Line Leak Detector <br />❑ Tank Overfill / High -Level Sensor <br />❑ Other (specify equipment in Section E) <br />Tank #3 (Product): Diesel <br />❑ In -Tank Gauging Probe <br />■ Annular Space or Vault Sensor <br />■ Piping Sump / Trench Sensor(s) <br />❑ Fill Sump Sensor(s) <br />❑ Mechanical Line Leak Detector <br />❑ Electronic Line Leak Detector <br />❑ Tank Overfill / High -Level Sensor <br />❑ Other (specify equipment in Section <br />Model: <br />Model: 0794390-420 <br />Model: 0794380-208 <br />Model: <br />Model: <br />Model: <br />Model: <br />Model: <br />Model <br />Model: 0794390-420 <br />Model: 0794380-208 <br />Model: <br />Model: <br />Model: <br />Model: <br />Model: <br />Tank #2 (Product): Gasoline - 91 <br />❑ In -Tank Gauging Probe <br />Model: <br />❑ Annular Space or Vault Sensor <br />Model: <br />■ Piping Sump / Trench Sensor(s) <br />Model: 0794380-208 <br />❑ Fill Sump Sensor(s) <br />Model: <br />❑ Mechanical Line Leak Detector <br />Model: <br />❑ Electronic Line Leak Detector <br />Model: <br />❑ Tank Overfill / High -Level Sensor <br />Model: <br />❑ Other (specify equipment in Section E) <br />Model: <br />Tank #4 (Product): _ <br />❑ <br />In -Tank Gauging Probe <br />Model: <br />❑ <br />Annular Space or Vault Sensor <br />Model: <br />❑ <br />Piping Sump / Trench Sensor(s) <br />Model: <br />❑ <br />Fill Sump Sensor(s) <br />Model: <br />❑ <br />Mechanical Line Leak Detector <br />Model: <br />❑ <br />Electronic Line Leak Detector <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor <br />Model: <br />❑ <br />Other (specify equipment in Section E) <br />Model: <br />1:01111111 al F.y», F,9 :iyf I I sTsiM <br />C. CERTIFICATION I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. <br />Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the <br />layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (check all that apply): <br />■ System set-up ■ Alarm History Report <br />Technician / Cert #: Bruce N. Stewart / A31131 5249892 -UT <br />WALTON <br />ENGINEERING, INC. <br />Date: March 26, 2009 <br />Dispenser # : 1-2 <br />■ Dispenser Containment Sensor(s) Model: 0794380-208 <br />❑ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : 3-4 <br />■ Dispenser Containment Sensor(s) Model: 0794380-208 <br />❑ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : 7-8 <br />■ Dispenser Containment Sensor(s) Model: 0794380-208 <br />❑ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser <br />■ <br />❑ <br />❑ <br /># : 5-6 <br />Dispenser Containment Sensor(s) Model: 0794380-208 <br />Shear Valves <br />Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : <br />❑ Dispenser Containment Sensor(s) Model: 0794380-208 <br />❑ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : 8 Sat <br />■ Dispenser Containment Sensor(s) Model: 0794380-208 <br />❑ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />C. CERTIFICATION I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. <br />Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the <br />layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (check all that apply): <br />■ System set-up ■ Alarm History Report <br />Technician / Cert #: Bruce N. Stewart / A31131 5249892 -UT <br />WALTON <br />ENGINEERING, INC. <br />Date: March 26, 2009 <br />