Laserfiche WebLink
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.or /q ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Faculty Nella Oil #487 DBA FI ers Faralrty 983 Moffat Blvd, Manteca, CA Inspection Jul 24, 2013 <br />Name: y Address: Date: <br />VIOLATIONS <br /># <br />C7 <br />CZ <br />M <br />Code Section <br />HSC = CA Health and SafetyCode; CFR = Code of Federal R ulations <br />C1 = Class 1 violation; C2 = Class 2 vWalion, M = Minor violation <br />Non -Pressured Piping (continued) <br />702 <br />CCR 2643(e) <br />Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (M1) <br />703 <br />CCR 2643(d) <br />Triennial lute test for conventional suction piping not performed (pre -January 1, 1984) (Mi) <br />Other Violations <br />999 Other: See attached "Continuation — Official Inspection Report" for violations) not listed above. <br />SUMMARY OF VIOLATIONS <br />CLASS 1, CLASS II, or MINOR -Notice to Comply) <br />Onsite to conduct a routine Underground Storage Tank (UST) inspection and witness a Monitoring <br />System Certification. <br />Class II Violations: (310 and 311) <br />310. Approximately 2.5 cups of liquid was observed in the diesel fuel STP sump and approximately 1.5 <br />cups of liquid was observed in the diesel UDC 7 sump. If water could enter into the secondary <br />containment by precipitation or infiltration, it must be removed and disposed of properly. Technician <br />removed the liquid and retained it for reuse. Ensure that the STP and UDC sumps are maintained free of <br />liquid. Violation corrected onsite. <br />311. The 87 -octane line leak detector failed to detect a leak when tested. All line leak detectors shall be <br />capable of detecting a 3 -gallon per hour leak at 10 psi. The service technician adjusted the leak <br />detector, replaced the syphon jet, service technician also replaced the VMI LD-2000-MLLD leak detector <br />with like for like, new serial number is 13041453. The technician retested the line leak detector and it <br />failed. Have a properly licensed, trained, and certified contractor repair or replace the failed leak detector <br />and obtain a permit within one business day from the EHD. If the failed leak detector can't be replaced <br />immediately, there is a possibility that the 87 -octane UST system may be red to prevent fuel inputs. <br />Minor -Notice to Comply Violation: (206) <br />206. The designated operator employee training was not performed. The last training took place on <br />6-11-20 . The designated operator shall train facility employees for which he or she is responsible in <br />the pr per operation and maintenance of the UST system once every 12 months. The training shall <br />inc de, but is not limited to: <br />y A r �4/�`"7 �M 7- U hit c d.�<<� �' I,.� 11 « rr'1 Nltnor Gle"�-op <br />,!�cT-i ansa <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO C PLY BY TME ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT END'S CURRENT HOURLY RATE. <br />Inspector. -7WO Recei Title: <br />2�%� "7e-, <br />=_HD 23 02 Rev 04/19/12 P4L 3 UST INSPECTION REPOR <br />