COMPLIANCE INFO_2001-2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MOSSDALE
>
444
>
2300 - Underground Storage Tank Program
>
PR0231692
>
COMPLIANCE INFO_2001-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 11:29:54 AM
Creation date
6/3/2020 9:51:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001-2009
RECORD_ID
PR0231692
PE
2361
FACILITY_ID
FA0000212
FACILITY_NAME
Mossdale Chevron
STREET_NUMBER
444
Direction
W
STREET_NAME
MOSSDALE
STREET_TYPE
RD
City
LATHROP
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
444 W MOSSDALE RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231692_444 W MOSSDALE_2001-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
358
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�IFIED PROGRAM CONSOLIDATED FOR*TANK: TA0508178 <br />PR #: PRO231692 <br />. <br />UNDERGROUND STORAGE TANKS - TANK PAGE I FAC #: FA0000212 <br />' <br />744103 (two pages per tank) <br />6 of 7 <br />TYPE OF ACTION ❑ 1 NEW SITE PERMIT ❑ 4 AMENDED PERMIT ❑ 5 CHANGE OF INFORMATIONPage <br />❑ 6 TEMPORARY SITE CLOSURE <br />(Check only Iran only) <br />❑ 7 PERMANENTLY CLOSED ON SITE <br />�..,�-s <br />1F' i RENEWAL PERMIT ME= ❑ 8 TANK REMOVED 430 <br />1191M <br />BUSINESS NAME Same m FACILITY NAME or DBA - Doing Business As <br />( g ) <br />FACILITY ID: <br />PR #: <br />I <br />MBP MOSSDALE* <br />3 FA0000212 <br />PR0231692 <br />LOCATION WITHIN SITE (optional) 444 W MOSSDALE RD, LATHROP 431 <br />PHONE <br />I. TANK DESCRIPTION (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br />TANK ID# Tank #: 6 432 <br />TANK MANUFACTURER D 433 <br />P <br />COMPARTMENTALIZED TANK ❑ <br />Yes No a34 <br />TA0508178 <br />RP <br />If "Yes", complete one page for each comment <br />part <br />DATE INSTALLE (YEAR/MO) 435 <br />TANK CAPACITY IN GALLONS 436 <br />NUMBER OF COMPARTMENTS 437 <br />4,000 <br />3 <br />ADDITIONAL DESd.RI DESTIO (For local use only) 438 <br />II. TANK CONTENTS <br />TANK USE 439 <br />PETROLEUM TYPE 440 <br />® 1. MOTOR VEHICLE FUEL <br />❑ la. REGULAR UNLEADED ❑ 2. LEADED ❑ 5. JET FUEL <br />(If narked complete Petroleum Type) <br />*l b. PREMIUM UNLEADED gF3. DIESEL ❑ 6. AVIATION FUEL <br />❑ 2. NON-FUEL PETROLEUM <br />❑ 1 c. MIDGRADE UNLEADED ❑ 4. GASOHOL ❑ 99. OTHER <br />❑ 3. CHEMICAL PRODUCT <br />COMMON NAME (fiwn Hazardous Materials hrvrn I� page) 441 <br />CAS# from Hazardous Materials Invent a <br />( Inventory page) g) 442 <br />E]4. HAZARDOUS WASTE <br />(Includes Used Oil) <br />❑ 95. UNKNOWN <br />III. TANK CONSTRUCTION <br />TYPE OF TANK ❑ 1. SINGLE WALL ❑ 3. SINGLE WALL WITH ❑ 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br />(Check one itemonly) EXTERIOR MEMBRANE LINER ❑ 95. UNKNOWN <br />® 2. DOUBLE WALL ❑ 4. SINGLE WALL IN VAULT ❑ 99. OTHER <br />TANK MATERIAL. - primary tank ® 1. BARE STEEL ❑ FIBERGLASS / PLASTIC ❑ 5. CONCRETE ❑ 95. UNKNOWN 444 <br />(Check one item only) ❑ 2. STAINLESS STEEL ❑ STEEL CLAD W/FIBERGLASS ❑ 8. FRP COMPTIBLE W/ 100% METHANOL <br />REINFORCED PLASTIC (FRP) ❑ 99. OTHER <br />TANK MATERIAL - secondary tank ❑ 1. BARE STEEL ❑ 3. FIBERGLASS / PLASTIC ❑ 5. CONCRETE ❑ 95. UNKNOWN 445 <br />(Check one item only) ❑ 2. STAINLESS STEEL�.4. STEEL CLAD W/FIBERGLASS E]8. FRP COMPTIBLE W/100%METHANOL <br />VXJREINFORCED <br />PLASTIC (FRP) ❑ 10. COATED STEEL ❑ 99. OTHER <br />❑ 5. CONCRETE <br />TANK INTERIOR LINING ❑ 1. RUBBER LINED ❑ 3. EPDXY LINING ❑ 5. GLASS LINING ❑ 95. UNKNOWN 446 DATE INSTALLED 447 <br />OR COATING <br />(Check one item only) ❑ 2 ALKYD LINING ❑ 4 PHENOLIC LINING ® 6 UNLINED ❑ 99. OTHER <br />(For local use only) <br />OTHER CORROSION ❑ I MANUFACTURING CATHODIC ® 3 FIBERGLASS REINFORCED PLASTIC ❑ 95 UNKNOWN 448 DATE INSTALLED 449 <br />PROTECTION IF APPLICABLE PROTECTION <br />(Check one item only) E]4 IMPRESSED CURRENT ❑ 99 OTHER <br />❑ 2 SACRIFICIAL ANODE (For local use only) <br />SPILL AND OVERFILL YEAR INSTALLE450 TYPE (local use only) 451 <br />OVERFILL PROTECTION EQUIPMENT: YEAR INSTALLED 452 <br />1 SPILL CONTAINMENT <br />(Check all that aPPIY) � � <br />❑ 1 ALARM �4EXEMPT 3 FILL TUBE SHUT OFF VAL` �2DROPTUBE <br />2BALL � <br />-�G <br />rG'\ STRIKER PLATE61 <br />FLOAT <br />IV. TANK LEAK DETECTION (A description of the monitoring program shall be subm tted to the local agency.) <br />IF SINGLE WALL TANK (Check all that apply) 453 <br />IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br />❑ 1 VISUAL (EXPOSED PORTION ONLY) ❑ 5 MANUAL TANK GAUGING (MTG) <br />(Check one item only) <br />❑ 2 AUTOMATIC TANK GAUGING (ATG) ❑ 6 VADOSE ZONE <br />❑ 1 VISUAL (SINGLE WALL IN VAULT ONLY) <br />❑ 3 CONTINUOUS ATG ❑ 7 GROUNDWATER <br />® 2 CONTINUOUS INTERSTITIAL MONITORING <br />❑ 4 STATISTICAL INVENTORY RECONCILIATION ❑ 8 TANK TESTING <br />❑ 3 MANUAL MONITORING <br />(SIR) BIENNIAL TANK TESTING ❑ 99 OTHER <br />V. TANK CLOSURE INFORMATION / PERMANENT CLOSURE IN PLACE <br />ESTIMATED DATE LAST USED (YR/MO/DAY) 455 <br />ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 <br />TANK FILLED WITH INERT MATERIAL? 457 <br />0.00 gallons <br />❑ Yes ❑ No <br />UPCF (12/99 revised) <br />
The URL can be used to link to this page
Your browser does not support the video tag.