COMPLIANCE INFO_2010-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MOSSDALE
>
444
>
2300 - Underground Storage Tank Program
>
PR0231692
>
COMPLIANCE INFO_2010-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 11:35:02 AM
Creation date
6/3/2020 9:51:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2015
RECORD_ID
PR0231692
PE
2361
FACILITY_ID
FA0000212
FACILITY_NAME
Mossdale Chevron
STREET_NUMBER
444
Direction
W
STREET_NAME
MOSSDALE
STREET_TYPE
RD
City
LATHROP
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
444 W MOSSDALE RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231692_444 W MOSSDALE_2010-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
428
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd/unitiii.htmi <br />CONTINUATION FORM <br />Page: 3 of 3 <br />OFFICIAL INSPECTION REPORT <br />Date: 05/23/11 <br />Facility Address: 444 Mossdale Road, Lathrop <br />Program: UST <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS 11, or MINOR -Notice to Comply) <br />UST Inspection Report <br />3. Facility lack new tank forms. Any change of information on these forms must be submitted to the <br />EHD within 30 days of the changes. Immediately complete and submit a copy of the facility and tank <br />forms to the EHD. Complete a separate tank form for each tank. <br />6. Approved copies of the monitoring and response plans were not found on site. Copies of these plans <br />shall be retained on site at all times. Immediately locate and retain a copy on site. <br />23c. The January, 2011, designated operator monthly inspection report was not found on site. <br />Designated operator monthly inspection reports for the previous twelve months shall be retained on site. <br />Locate and ensure that copies of the previous twelve months of designated operator monthly inspection <br />reports are maintained on site. Submit copies to the EHD within 30 days of receiving this report. The <br />DO for the facility was on site at the time of inspection and provided a reprint of the January, 2011, <br />report. <br />23d. The designated operator employee training for Jagi and Sandi, hired in November, 2010, was not <br />performed. The designated operator shall train facility employees for which he or she is responsible in <br />the proper operation and maintenance of the UST system once every 12 months. The training shall <br />include, but is not limited to: <br />1. Operation of the UST system in a manner consistent with the facility's best management practices <br />2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br />3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br />4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br />Ensure that employees have been trained by the designated operator, maintain the list on site, and <br />submit a copy of the training records to the EHD within 30 days of receiving this report. <br />Notes <br />Complete and submit a copy of the Return to Compliance Certification form with a statement of how <br />each violation was corrected, including supporting documentation, within 30 days of receiving this report. <br />Provided blank tank forms to be fill out by the facility and submitted to this office <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE ($122. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />EHD Inspector: <br />Received By: <br />Title: <br />EHD 23-02-003 Rev 08/10/10 I CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.