Laserfiche WebLink
OUTPUT RELAY SETUP <br />TANK #: 2 <br />LIQUID SENOR SETUP <br />S <br />R 1:UNLEADED STP <br />— — — — — — — — — — — — <br />TYPE: <br />STANDARD <br />LIQUID SENSOR ALMS <br />L 1:UNLEADED SUMP <br />NORMALLY CLOSED <br />L I:FUEL ALARM <br />TRI—STATE (SINGLE FLOAT) <br />L 2:FUEL ALARM <br />CATEGORY : STP SUMP <br />TANK #: 1 <br />L 3:FUEL ALARM <br />L 4:FUEL ALARM <br />L 5:FUEL ALARM <br />L 2:PREMIUM SUMP <br />LIQUID SENSOR ALMS <br />L 6:FUEL ALARM <br />TRI—STATE (SINGLE FLOAT) <br />L l:FUEL ALARM <br />L 7:FUEL ALARM <br />CATEGORY : ---TP SUMP <br />L 5:FUEL ALARM <br />L 8:FUEL ALARM <br />L 6:FUEL ALARM <br />L 9:FUEL ALARM <br />L ":FUEL ALARM <br />1-10:FUEL ALARM <br />L 3:DIESEL SUMP <br />L Be:FUEL ALARM <br />L 2:SENSOR OUT ALARM <br />TRI—STATE (SINGLE FLOAT) <br />L 9:FUEL ALARM <br />L 5:SENSOR OUT ALARM <br />CATEGORY : STP SUMP <br />LIO:FUEL ALARM <br />L 6:SENSOR OUT ALARM <br />L I:SENSOR OUT ALARM <br />L 7:SENSOR OUT ALARM <br />L 5:SENSOR OUT ALARM <br />1, 8:SENSOR OUT ALARM <br />L 4:ANNULAR SPACE <br />L 6:SENSOR OUT ALARM <br />L 9:SENSOR OUT ALARM <br />TRI—STATE (SINGLE FLOAT) <br />L 7:SENSOR OUT ALARM <br />LIO:SENSOR OUT ALARM <br />CATEGORY : ANNULAR SPACE <br />L 8:SENSOR OUT ALARM <br />L 2:SHORT ALARM <br />L 9:SENSOR OUT ALARM <br />L 5:SHORT ALARM <br />LIO:SENSOR OUT ALARM <br />L 6:SHORT ALARM <br />L I:SHORT ALARM <br />L 7:SHORT ALARM <br />L 5:DISP 1-2 <br />L 5:SHORT ALARM <br />L 8:SHORT ALARM <br />TRI—STATE (SINGLE FLOAT) <br />L 6:SHORT ALARM <br />L 9:SHORT ALARM <br />I <br />CATEGOR" : DISPENSER PAN <br />L 7:SHORT ALARM <br />1-10:SHORT ALARM <br />L 8:SHORT ALARM <br />L 2: WATER ALARM <br />L 9:SHORT ALARM <br />L 5:WATER ALARM <br />LIO:SHORT ALARM <br />L 6:WATER ALARM <br />L 6:DISP 2-4 <br />L I:WATER ALARM <br />L 7:WATER ALARM <br />TRI—STATE (SINGLE FLOAT) <br />L 5:WATER ALARM <br />L 8:WATER ALARM <br />CATEGORY : DISPENSER PAN <br />L 6:WATER ALARM <br />L 9:14ATER ALARM <br />L 7:WATER ALARM <br />LIO:WATER ALARM <br />L 8:WATER ALARM <br />L 9:WATER ALARM <br />ISD SITE ALARMS <br />L 7:DISP 5-6 <br />LIO:WATER ALARM <br />IS GROSS PRES FAIL <br />TRI—STATE (SINGLE FLOAT) <br />ISD DEGRD PRES FAIL <br />CATEGORY : DISPENSER PAN <br />ISD SITE ALARMS <br />ISD GROSS PRES FAIL <br />ISD VAPOR LEAK FAIL <br />ISD DEGRD PRES FAIL <br />ISD VP PRES FAIL <br />L 8:DISP 7-8 <br />ISD VAPOR LEAK FAIL <br />ISD VP STATUS FAIL <br />ISD VP PRES FAIL <br />ISD SETUP FAIL <br />TRI—STATE (SINGLE FLOAT) <br />ISD VP STATUS FAIL <br />ISD SENSOR OUT FAIL <br />CATEGORY : DISPENSER PAN <br />ISD SETUP FAIL <br />ISD HOSE ALARMS <br />ISD SENSOR OUT FAIL <br />ALL:GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT FAIL <br />L 9:DISP 9-10 <br />ISD HOSE ALARMS <br />ALL:FLOW COLLECT FAIL <br />TRI—STATE (SINGLE FLOAT) <br />ALL:GROSS COLLECT FAIL <br />CATEGORY : DISPENSER PAN <br />ALL:DEGRD COLLECT FAIL <br />R 3:DIESEL STP <br />ALL:FLOkJ COLLECT FAIL <br />TYPE: <br />STANDARD <br />R 2:PREM IUM STP <br />NORMALLY CLOSED <br />LIO:DISP 11-12 <br />TYPE: <br />TRI—STATE (SINGLE'FLOAT) <br />STANDARD <br />CATEGORY : DISPENSER PAN <br />NORMALLY CLOSED <br />