My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1986-2001
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
O
>
OLIVE
>
1030
>
2300 - Underground Storage Tank Program
>
PR0231704
>
COMPLIANCE INFO_1986-2001
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 8:54:53 AM
Creation date
6/3/2020 9:51:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-2001
RECORD_ID
PR0231704
PE
2361
FACILITY_ID
FA0001060
FACILITY_NAME
QUIK STOP MARKET #2076*
STREET_NUMBER
1030
Direction
S
STREET_NAME
OLIVE
STREET_TYPE
ST
City
STOCKTON
Zip
95215
APN
157-264-22
CURRENT_STATUS
01
SITE_LOCATION
1030 S OLIVE ST
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231704_1030 S OLIVE_1986-2001.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
463
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FRONT VIEW <br />BOTTOM VIEW <br />9-11/16" <br />3/4", 1", 1-1/4" Knockouts <br />(Top & Bottom) <br />To Power Area To Intrinsically <br />Safe Area <br />19.3/4" <br />FRONT VIEW <br />12-1/4' <br />&5118' - 2'-r <br />Gilbarco <br />A EMG <br />Power. <br />120V AC. 50/60 Hz. <br />Alarm rela%s: 2304 AC. 2 amp maximum. <br />Printer. <br />Thermal printer. 2-1/4- paper. For best results, use <br />paper recommended by Gilbarco. <br />Display. <br />LCD display. Two lines, twenty-four characters per <br />line. Alarm. Warning. and Power indicators. <br />Ordering. <br />PA02620100000 ENIC Environmental Management <br />Console With Printer <br />PA02620000000 EMC Environmental Management <br />Console Without Printer <br />Your Gilbarco distributor can assist you in determining <br />which modules. probes, and sensors will best suit your <br />particular needs. <br />Choose from these EMC Environmental <br />Management Console modules: <br />• In -Tank Monitoring Module <br />• Volumetric Line Leak Detection Module <br />—,— • Vapor Detection Module <br />is Groundwater Monitoring Module <br />• Interstitial Space :and Sump Monitoring Module <br />- • Output Module <br />• InpuVOutput Combination Module <br />• RS -232 Serial Port Module <br />• Internal Modem Module <br />• Printer Module <br />UL Listed. CSA Approved model is also available. <br />Product specifications are subject to change. <br />A WeR1 <br />Power. <br />120V AC. 50/60 Hz. <br />Alarm relays: 230V AC. 2 amp maximum. <br />Display. <br />LCD display. Two lines, twenty-four characters per <br />line. Alarm, Warning, and Power indicators. <br />Ordering. <br />PA02740000000 EMC External Sensor System <br />Your Gilbarco distributor can assist you in <br />determining which modules and sensors will best <br />suit your particular needs. <br />Choose from these EMC External Sensor System <br />modules: <br />• Vapor Detection .and Groundwater <br />Monitoring Module <br />• Interstitial Space And Sump <br />Monitoring Module <br />UL Listed. CSA Approved model is also available. <br />Product specifications are subject to change. <br />IN111117 <br />5 <br />BOTTOM VIEW <br />12-1/4' <br />To Power Area <br />To Int <br />3/4', 1', Knockouts <br />(Top & Bottom) <br />. <br />� . <br />e A.8 <br />- N Safe Area <br />cl <br />io e <br />Mex. Caoactry (20) <br />14 AWG. Wires <br />`" <br />` <br />�' x•5!76• _.. " <br />l-3/4' —• <br />314', 1', 1.1/4' Knockoub <br />(Top & Bottom) <br />Mex. Capacity (50) 14 <br />AWG. Thin. Wires <br />Power. <br />120V AC. 50/60 Hz. <br />Alarm rela%s: 2304 AC. 2 amp maximum. <br />Printer. <br />Thermal printer. 2-1/4- paper. For best results, use <br />paper recommended by Gilbarco. <br />Display. <br />LCD display. Two lines, twenty-four characters per <br />line. Alarm. Warning. and Power indicators. <br />Ordering. <br />PA02620100000 ENIC Environmental Management <br />Console With Printer <br />PA02620000000 EMC Environmental Management <br />Console Without Printer <br />Your Gilbarco distributor can assist you in determining <br />which modules. probes, and sensors will best suit your <br />particular needs. <br />Choose from these EMC Environmental <br />Management Console modules: <br />• In -Tank Monitoring Module <br />• Volumetric Line Leak Detection Module <br />—,— • Vapor Detection Module <br />is Groundwater Monitoring Module <br />• Interstitial Space :and Sump Monitoring Module <br />- • Output Module <br />• InpuVOutput Combination Module <br />• RS -232 Serial Port Module <br />• Internal Modem Module <br />• Printer Module <br />UL Listed. CSA Approved model is also available. <br />Product specifications are subject to change. <br />A WeR1 <br />Power. <br />120V AC. 50/60 Hz. <br />Alarm relays: 230V AC. 2 amp maximum. <br />Display. <br />LCD display. Two lines, twenty-four characters per <br />line. Alarm, Warning, and Power indicators. <br />Ordering. <br />PA02740000000 EMC External Sensor System <br />Your Gilbarco distributor can assist you in <br />determining which modules and sensors will best <br />suit your particular needs. <br />Choose from these EMC External Sensor System <br />modules: <br />• Vapor Detection .and Groundwater <br />Monitoring Module <br />• Interstitial Space And Sump <br />Monitoring Module <br />UL Listed. CSA Approved model is also available. <br />Product specifications are subject to change. <br />IN111117 <br />5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.