My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
O
>
OLIVE
>
1030
>
2300 - Underground Storage Tank Program
>
PR0231704
>
COMPLIANCE INFO_2002-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 8:59:27 AM
Creation date
6/3/2020 9:51:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2007
RECORD_ID
PR0231704
PE
2361
FACILITY_ID
FA0001060
FACILITY_NAME
QUIK STOP MARKET #2076*
STREET_NUMBER
1030
Direction
S
STREET_NAME
OLIVE
STREET_TYPE
ST
City
STOCKTON
Zip
95215
APN
157-264-22
CURRENT_STATUS
01
SITE_LOCATION
1030 S OLIVE ST
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231704_1030 S OLIVE_2002-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
264
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDER DISPSER CONTAINMENT t DC) TESTING <br />Test Method By: o Manufacturer <br />Test Method Uses: O Pressure <br />Measuring Equipment Used: INCON <br />• Industry Standard o Professional Engr o Other (see below) <br />O vacuum i Hydrostatic o Other (see below) <br />TS -STS (Electronic Sump Test System) <br />Description <br />Disp # 1/2 <br />Disp # 3/4 <br />Test start time <br />UDC manufacturer <br />UDC material <br />UDC depth (inches) <br />Height from UDC bottom to highest <br />piping penetration <br />Bravo <br />Steel <br />9" <br />Bottom <br />Bravo <br />Steel <br />9" <br />Bottom <br />1.6668 <br />1.9480 <br />Height from UDC bottom to lowest <br />electrical penetration <br />Bottom <br />Bottom <br />Test duration (hemin) <br />Change in water level (t 0.0000 inches) <br />0:15 <br />0.0002 <br />Condition of UDC prior to testing <br />Dry <br />Dry <br />0.0020 <br />TEST RESULT <br />Port <br />PASS <br />ion of UDC tested <br />Entire <br />Entire <br />Type of shut -down present <br />Float <br />Float <br />Was sensor removed for testing? <br />NIA <br />N/A <br />Was sensor properly replaced after testing? <br />N/A <br />N/A <br />Depth of water level from UDC bottom (in.) <br />Comments: <br />6" <br />6" <br />Wait time for water level to stabilize (hrmin) <br />0:11 <br />0:04 <br />Test start time <br />12:40 PM <br />12:40 PM <br />Initial Probe Reading <br />1.6668 <br />1.9480 <br />Test end time <br />Final Probe Reading <br />12:55 PM <br />1.6670 <br />12:55 PM <br />1.9478 <br />Test duration (hemin) <br />Change in water level (t 0.0000 inches) <br />0:15 <br />0.0002 <br />0:15 <br />-0.0002 <br />Pass/Fail threshold (10.0020 inches Hr.) <br />0.0020 <br />0.0020 <br />TEST RESULT <br />PASS <br />PASS <br />ion of UDC tested <br />Entire <br />Entire <br />Type of shut -down present <br />Float <br />Float <br />Was sensor removed for testing? <br />NIA <br />N/A <br />Was sensor properly replaced after testing? <br />N/A <br />N/A <br />Depth of water level from UDC bottom (in.) <br />Comments: <br />6" <br />6" <br />Wait time for water level to stabilize (hrmin) <br />0:11 <br />0:04 <br />Test start time <br />12:40 PM <br />12:40 PM <br />Initial Probe Reading <br />1.6668 <br />1.9480 <br />Test end time <br />Final Probe Reading <br />12:55 PM <br />1.6670 <br />12:55 PM <br />1.9478 <br />Test duration (hemin) <br />Change in water level (t 0.0000 inches) <br />0:15 <br />0.0002 <br />0:15 <br />-0.0002 <br />Pass/Fail threshold (10.0020 inches Hr.) <br />0.0020 <br />0.0020 <br />TEST RESULT <br />PASS <br />PASS <br />2004 Walton Engineering, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.