Laserfiche WebLink
LINE LEAVPETECTOR (LLD) TEff REPORT <br />TEST DATE: July 20, 2009 <br />Al. FACILITY <br />A2. OWNER <br />Name <br />Quik Stop Market # 76 <br />Name <br />Name <br />Quik Stop Markets, Inc. <br />Address <br />1030 S. Olive Avenue, Stockton, CA 95215 <br />P.O. Box 1025, W. Sacramento, CA 95691 <br />Address <br />4567 Enterprise Street, Fremont, CA 94538 <br />Phone # <br />510-657-8500 <br />Inspector <br />Phone # <br />510-657-8500 <br />Contact <br />Michael Karvelot <br />209-468-3439 <br />Contact <br />Michael Karvelot <br />A3. C U P A <br />A4. TESTING CONTRACTOR <br />Name <br />San Joaquin County Environmental Health <br />Name <br />Walton Engineering, Inc. <br />Address <br />600 E. Main Street, Stockton, CA 95202 <br />Address <br />P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified <br />July 17, 2009 <br />Lic # <br />617238 A, B, Haz <br />Inspector <br />Jeff Wong <br />Contact <br />Richard Walton <br />Phone # <br />209-468-3439 <br />Phone # <br />916-825-3203 <br />I. MECHANICAL LINE LEAK DETECTOR TEST RESULTS <br />Test Equipment Used: Vaporless VMI LDT-890 <br />Tank number <br />1 <br />2 <br />Product contained <br />Gasoline - 87 <br />Gasoline - 91 <br />Leak Detector Type <br />MLLD <br />MLLD <br />Leak detector make/model <br />FE Petro STP -MLD <br />FE Petro STP -MLD <br />Serial number <br />3051099 <br />3080062 <br />Functional Element Holding (psi) <br />20 <br />4 <br />Resiliency (ml) <br />130 <br />100 <br />Test leak rate (gph) <br />3.00 <br />3.00 <br />28 <br />28 <br />8 <br />9 <br />20 <br />19 <br />30 <br />30 <br />5 <br />4 <br />PASS <br />PASS <br />Pump pressure (psi) <br />Metering pressure (psi) <br />Pressure Restriction Reduction (psi) <br />Length of Restriction Test (seconds) <br />Full Flow Opening time (seconds) <br />TEST RESULT <br />Tank number <br />Product contained <br />Leak Detector Type <br />Leak detector make/model <br />Serial number <br />Functional Element Holding (psi) <br />Resiliency (ml) <br />Test leak rate (gph) <br />Pump pressure (psi) <br />Metering pressure (psi) <br />Pressure Restriction Reduction (psi) <br />Length of Restriction Test (seconds) <br />Full Flow Opening time (seconds) <br />TEST RESULT <br />J. COMMENTS: <br />WALTON <br />Signature: a ENGINEERING, INC. <br />Technician: Jessie Wadkins / B35391 5307886 -UT Date: July 20, 2009 <br />