Laserfiche WebLink
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax. (209) 468-3433 Web: www.sjgov.org/eh <br />Facility name: <br />Designated Operator: <br />Inspection Date: <br />-7/ -2-1 <br />Facility address: <br />UST # 7 <br />-P or --2 <br />Facility Contact: <br />Tittf: Phone: <br />UL <br />Monitoring Panel: <br />19 :a-12 35k>- , <br />Piping <br />Piping system: <br />ressurized 11 Suction El Gravity <br />- <br />Overfill prevention: <br />echanical El Audible/visual <br />type: Violations: <br />36outine onitoring Certification 11 Installation 11 Other: F1 M I - RDetect D M2-RPrev <br /># Code Section VIOLATION(S) HSC=Califomia Health & Safety Code; CCR=Califomia Code of Regulations <br />V=Violation; RV=Repeat Violation <br />�N-3 Both <br />V R <br />V <br />I <br />HSC 25284 <br />Permit too2erate <br />2 <br />CCR 2637 <br />Seconds containment test performed <br />3 <br />CCR 2711 (b) & (c) <br />Current Unified Program Consolidated Forms on file with EHD (Facility and tank form) <br />4 <br />HSC 25292.2 <br />Certification of financial responsibility and CFO letter <br />5 <br />CCR 2632 (b <br />Monitoring Program (Monitoring & Response Plan) is current and a2)roved by the local agency. <br />6 <br />CCR 2712 (i) <br />Monitorin1an is onsite. <br />7 <br />CCR 2712 (b) <br />Maintenance & monitoring records <br />(M 1) <br />8 <br />CCR 2643 (d) <br />"Daily monitoring ofsuction piping (pre-Janusly, 1, 1984) <br />9 <br />1 HSC 25292.1 <br />UST system isoperated to prevent unauthorized release <br />10 <br />CCR 2632 (c) 2) <br />UST monitoring system is present <br />(M 1) <br />I I <br />CCR 2630 d) <br />UST system monitonina equipment is properly located to detect a leak <br />(M 1) <br />12 <br />HSC 25291 b) <br />UST system monitoring equi2ment isoperational <br />( 2) <br />13 <br />CCR 2636 l) <br />Continuous monitoring system for underground 2i2ing & UDC is present <br />(M 1) <br />14 <br />CCR 2631 (a) <br />PtTLry containment is product tiht <br />15 <br />1 HSC 25291 (a)(2) <br />Secondary containment for UST is tight <br />16 <br />CCR 2636 (c)(1) <br />All releases in secondary piping flow to a collection sump <br />17 <br />HSC 25291 (f) <br />Line leak detectors ) are installed <br />(M1) <br />1 1 <br />18 <br />CCR 2635 (b)(1) <br />Spill container <br />(M2) <br />19 <br />CCR 2635 (b)(2) <br />Overfill 2revention system <br />(M2) <br />20 <br />21 <br />CCR 2636 (a) <br />HSC 25291 (e) <br />Conventional suction piping shall have continuous monitoring & 2' containment <br />Water in 2' containment analyzed & properly disposed of <br />22 <br />CCR 2650 <br />RecordinE/r2oqing of unauthorized releases <br />23 <br />CCR 2715 <br />Designated (a) Statement from UST owner; (c -e) Monthly inspection; (f) Employee training <br />24 <br />CCR 2638 (a) <br />'02crator: <br />Annual monitoring certification <br />25 <br />CCR 2638 (a) <br />Annual line leak detector test <br />(M1) <br />26 <br />HSC 25284.2 <br />Annual Spill containment testing <br />27 <br />CCR 2636 (f)(4 <br />Annual line tightness test <br />(M 1) <br />28 <br />CCR 2661 <br />Re air for tank/piping has had tiEhtness test <br />(M2) <br />29 <br />CCR 2643 e) <br />Biennial tightness test of gravity 2i2inre-Janus a 1, 1984) <br />30 <br />CCR 2643 (d) <br />Triennial line test for conventional suction piping (re -Janus a 1, 1984 <br />(M1) <br />31 <br />HSC 25292.5 <br />Double walls stem located within 1000' of2ublic well-ELD <br />32 <br />CCR 2661 <br />Permit to Mair UST system <br />33 <br />1 HSC 25286 (a <br />Permit to alter monitorinE system <br />34 <br />HSC 25298 (b) <br />Permit to tem2orarily close UST system <br />35 <br />HSC 25298 (c) <br />Permit to close UST system <br />36 <br />HSC 25299 a) 9) <br />DisablinF, leak detection devices <br />37 <br />HSC 25298 (a) <br />��ndonment of UST system <br />38 Other: _ <br />EHD INS PHONE: <br />RECEIVEY TITLE: <br />,OV <br />UIC <br />Septic system: <br />- Serves 2:20 people/day <br />sanitary - Receives other than sanitawaste <br />Other disposal methods: <br />Dry wells/French Drains <br />EHD 23-02-002 REV 05/07 <br />