My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
O
>
OLIVE
>
1030
>
2300 - Underground Storage Tank Program
>
PR0231704
>
COMPLIANCE INFO_2008-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 9:01:55 AM
Creation date
6/3/2020 9:51:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2012
RECORD_ID
PR0231704
PE
2361
FACILITY_ID
FA0001060
FACILITY_NAME
QUIK STOP MARKET #2076*
STREET_NUMBER
1030
Direction
S
STREET_NAME
OLIVE
STREET_TYPE
ST
City
STOCKTON
Zip
95215
APN
157-264-22
CURRENT_STATUS
01
SITE_LOCATION
1030 S OLIVE ST
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231704_1030 S OLIVE_2008-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
274
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PRODUCT PIPING SUMP TESTING <br />Test Method By: O Manufacturer 0 Industry Standard o Professional Engr o Other (see below) <br />Test Method Uses: O Pressure O vacuum • Hydrostatic o Other (see below) <br />Measuring Equipment Used: INCON TS -STS (Electronic Sump Test System) <br />Descrintion Tank #1 Tank #2 <br />Tank product <br />Gasoline - 87 <br />Gasoline - 91 <br />Sump material <br />FRP <br />FRP <br />Sump diameter (inches) <br />48" <br />48" <br />Sump depth (inches) <br />71" <br />72" <br />Height from tank top to highest <br />piping penetration (inches) <br />20" <br />21" <br />Height from tank top to lowest <br />electrical penetration (inches) <br />24 <br />17" <br />Method of sump attachment to tank <br />Tank Collar <br />Tank Collar <br />Condition of sump prior to testing <br />Dry <br />Portion of sump tested <br />Entire <br />Is system programmed for fail-safe operation? <br />Unknown <br />Was fail-safe verified to be operational? <br />No <br />Was sensor removed for testing? <br />Yes <br />Was sensor properly replaced after testing? <br />Yes <br />Depth of water level from tank top (inches) <br />22 <br />Wait time for water level to stabilize (hr:min) <br />0:10 <br />Test start time <br />9:45 AM <br />Initial Probe Reading <br />3.7212 <br />Test end time <br />10:00 AM <br />Final Probe Reading <br />3.7203 <br />Test duration (hr:min) <br />0:15 <br />Change in water level (± 0.0000 inches) <br />-0.0009 <br />Pass/Fail threshold (±0.0020 inches / Hr.) <br />0.0020 <br />TEST RESULT <br />PASS <br />Comments: <br />This is a test of the secondary lines, piping sump #1 and UDC's only. <br />0 2006 Walton Engineering, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.