My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
O
>
OLIVE
>
1030
>
2300 - Underground Storage Tank Program
>
PR0231704
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 9:07:22 AM
Creation date
6/3/2020 9:51:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231704
PE
2361
FACILITY_ID
FA0001060
FACILITY_NAME
QUIK STOP MARKET #2076*
STREET_NUMBER
1030
Direction
S
STREET_NAME
OLIVE
STREET_TYPE
ST
City
STOCKTON
Zip
95215
APN
157-264-22
CURRENT_STATUS
01
SITE_LOCATION
1030 S OLIVE ST
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231704_1030 S OLIVE_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
344
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CECEIVED <br /> OCT 2 7 201 <br /> PRODUCT PIPING I <br /> EUYIBQNMENTAL HEALTH <br /> DEPARTMENT <br /> Test Method By: O Manufacturer • Industrystandard o Professional Engr o Other(see below) <br /> Test Method Uses: o Pressure o Vacuum ® Hydrostatic o Other(see below) <br /> Measuring Equipment Used: INCON TS-STS (Electronic Sump Test System) <br /> Description Tank#1 Tank#2 <br /> Tank product Gasoline-87 Gasoline-91 <br /> Sump material FRP FRP <br /> Sump diameter (inches) 48 48 <br /> Sump depth (inches) 71 72 <br /> Height from tank top to highest 20 21 <br /> piping penetration (inches) <br /> Height from tank top to lowest 16 17 <br /> electrical penetration (inches) <br /> Method of sump attachment to tank Tank Collar Tank Collar <br /> Condition of sump prior to testing Dry Dry <br /> Portion of sump tested Entire Entire <br /> Is system programmed for fail-safe operation? Unknown Unknown <br /> Was fail-safe verified to be operational? No No <br /> Was sensor removed for testing? Yes Yes <br /> Was sensor properly replaced after testing? Yes Yes <br /> Depth of water level from tank top (inches) 22 23 <br /> Wait time for water level to stabilize (hr:min) :10 :15 <br /> Test start time 9:40 AM 9:40 AM <br /> Initial Probe Reading 2.5606 5.9006 <br /> Test end time 9:55 AM 9:55 AM <br /> Final Probe Reading 2.5596 5.9011 <br /> Test duration (hr:min) 0:15 0:15 <br /> Change in water level (±0.0000 inches) -0.0010 0.0005 <br /> Pass/Fail threshold (±0.002 inches/'41-11r.) 0.0020 0.0020 <br /> TEST RESULT PASS PASS <br /> Comments: <br /> 0 2016 Walton Engineering,Inc. <br />