My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1985-1998
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
STIMSON
>
2000
>
2300 - Underground Storage Tank Program
>
PR0231732
>
COMPLIANCE INFO_1985-1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2024 4:16:30 PM
Creation date
6/3/2020 9:51:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-1998
RECORD_ID
PR0231732
PE
2361
FACILITY_ID
FA0003648
FACILITY_NAME
STKN ARMY AVIATION SUPP FACILITY*
STREET_NUMBER
2000
STREET_NAME
STIMSON
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
17726004
CURRENT_STATUS
01
SITE_LOCATION
2000 STIMSON RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231732_2000 STIMSON_1985-1998.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
573
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I1111 <br />Delta <br />AkEnvironmental <br />Consultants, Inc. <br />3330 Data Drive, Suite 100 <br />Rancho Cordova, CA 95670 <br />916/638-2085 <br />FAX: 916/638-8385 <br />r <br />December 17, 1990 <br />Mr. Bill Gard <br />President <br />Delta Bay Builders, Inc. <br />Post Office Box 99 <br />Antioch, California 94509 <br />Subject: Soil Analytical Results <br />2000 Stinson Street, Stockton, California <br />Delta Project No. 40-90-024 <br />Dear Mr. Gard: <br />On October 24, 1990, Delta Environmental Consultants, Inc. (Delta), collected three soil samples <br />approximately five and a half feet below the north end of the concrete slab used to anchor the former <br />underground storage tanks at the subject site (see enclosed figure). Methods used for the collection of <br />these soil samples are described in Enclosure A. Ground water was not encountered in any of these <br />hand borings. No odor or discoloration of the soil was noticed in soil Samples Nos. 1 and 2. Soil <br />Sample No. 3 had a slight petroleum odor and was slightly discolored. Soil sample analytical results are <br />summarized in Table 1. Copies of the certified laboratory analytical results are contained in <br />Enclosure B. <br />TABLE 1 <br />Soil Sample Analytical Results <br />Concentrations in Parts Per Million (ppm) <br />October 24, 1990 <br />Practical Solutions to Environmental Concerns <br />Depth (feet <br />Ethyl- <br />TPH as <br />TPH as <br />Location <br />below grade) <br />Benzene <br />Toluene <br />benzene <br />Xylenes <br />Diesel <br />Jet Fuel <br />HB -1 <br />5.5 <br /><0.005 <br /><0.005 <br /><0.005 <br /><0.005 <br /><1.0 <br /><1.0 <br />HB -2 <br />5.5 <br /><0.005 <br /><0.005 <br /><0.005 <br /><0.005 <br /><1.0 <br /><1.0 <br />HB -3 <br />5.5 <br /><0.005 <br /><0.005 <br /><0.005 <br /><0.005 <br />11 <br />14 <br />Practical Solutions to Environmental Concerns <br />
The URL can be used to link to this page
Your browser does not support the video tag.