Laserfiche WebLink
323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status ❑V ❑R ❑COS <br /> 324 CCR 2717.1(g) Tampered with red tag — ❑V ❑R ❑COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST ❑V ❑R ❑COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms ❑V ❑R ❑COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored ❑V ❑R ❑COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements ❑V ❑R ❑COS <br /> 329 HSC 25298 Failed to comply with all permanent closure requirements ❑V ❑R ❑COS <br /> 330 CCR 2636(f),2666(c), No LLD on the emergency generator that restricts or shuts off the flow or triggers an alarm ❑V ❑R ❑COS <br /> 2666(f) <br /> 331 CCR 2630(d),2641(a) Liquid does not flow into the sump in the event of a leak(i.e.,failure to remove test boot). ❑V ❑R ❑COS <br /> 332 CCR 2631(b&d), Primary and/or secondary containment not constructed in accordance with the established standards ❑V ❑R ❑COS <br /> 2666(b&e) <br /> 333 CCR 2635,2636(b), Failure to comply with the cathodic protection system requirements ❑V ❑R ❑COS <br /> 2662,2712 <br /> 334 CCR 2666(b)(2) Single-walled pipe not upgraded to double-walled interstitially monitored pipe during repair ❑V ❑R ❑COS <br /> 335 CCR 2630,2632,2643, Equipment or methods used to monitor the UST system are not certified by an independent third-party ❑V ❑R ❑COS <br /> 2644.1 <br /> P <br /> t� fi <br /> .,.,.ra u<.,.,N 3- ,r;..s x� x a}v `15., ,.:.�. f �, x a .'t r n r ar'^. „tib i}3 ,1.,, `3 •,`" � t.'. ;4 t s���: <br /> 401 CCR 2636(a)(3), Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 2641(b) <br /> 402 CCR 2643(d) No monitoring or record maintenance for single-walled conventional suction systems(pre-Jan 1984). ❑V ❑R ❑COS <br /> 403 CCR 2643(d),2661(0 Failure to conduct 0.1 gph test for single-walled conventional suction systems(pre-Jan 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e),2661(f) Biennial 0.1 gph line integrity test for single-walled gravity piping not performed(pre-Jan 1984) ❑V ❑R ❑COS <br /> £ X <br /> J >~ <br /> i as i <br /> „ ;. « <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www_sjgov_org/ehd <br /> .;• � <br /> ttu4,y" `ia �q - 5 1k� `. <br /> } r r i'`'>,•' s:: r. t ,s: f.,"Ur..s., ,. t tir ,..z,, 'r -,°:a, ,s.,.st'e;, r .,^ a r ' fi'?",4L , s»»'u}tcrrat tx :,`i_. <br /> rr <br /> }9ME <br /> Facility Name: STKN ARMY AVIATION Facility Address: 2000 STIMSON Date:October 05, <br /> SUPP FACILITY* , ST C T 2018 <br /> gg, <br /> . i..� }ssi,rxiz#j? <br /> £�": z ' <br /> 2010 1 See below Unlisted General violation ❑V ❑R ❑COS <br /> W� m. <br /> Item# Remarks <br /> FA0003648 PR0231732 SC001 10/05/2018 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 5 Underground Storage Tank Program OIR <br />