My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
3032
>
2300 - Underground Storage Tank Program
>
PR0231758
>
COMPLIANCE INFO_2007-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2023 2:40:58 PM
Creation date
6/3/2020 9:52:06 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2012
RECORD_ID
PR0231758
PE
2361
FACILITY_ID
FA0002127
FACILITY_NAME
WESTERN FOOD & FUEL
STREET_NUMBER
3032
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3032 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231758_3032 E WATERLOO_2007-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
340
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN (Page 2 of 2) <br /> VI.UNDER DISPENSER CONTAINMENT(UDC)MONITORING <br /> -54 <br /> 1.)JDC MONITORING IS PERFORMED USING rWC LOWING 13AV490 <br /> METHOD A- <br /> ,0 490-54b <br /> )E <br /> ,01 CONTINUOUS ELECTRONIC MONITORING T AND CHAIN ASSEMBLY 0 3.ELECTRONIC STAND-ALONE <br /> ❑4.NO DISPENSERS 0 99.OTHER(Specify): /-S <br /> PANEL MANUFACTURER: ZN C&A)r 4-11 1 MODEL#: 490-56 <br /> LEAK SENSOR MANUFACTURER: ; - 7m6vA2 490-11 1 MODEL#(S): 7 vt— 490-58 <br /> DETECTION OF A LEAK INTO THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS [3 a.YES 0 b.NO 490-59 <br /> UDC LEAK ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN 0 a.YES 0 b.NO 490-60. <br /> FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. [I a.YES C1 b.NO 490-61 <br /> UDC MONITORING STORS THE FLOW OF PRODUCT AT THE DISPENSER 0 a.YES 0 b.NO 490-62 <br /> 2.UDC CONSTRUCTION IS ffl.SINGLE-WALLED 0 2.DOUBLE-WALLED 490-63 <br /> IF DOUBLE WALLED: 490-6aa <br /> UDC INTERSTITIAL SPACE IS MONITORED BY: [3 1.LIQUID Q 2.PRESSURE C]3.VACUUM <br /> A LEAK WITHIN THE SECONDARY CONTAINMENT OF THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS 13&YES 0 b.NO 4—b <br /> VII.PERIODIC SYSTEM TESTING <br /> [3 1. ELD TESTING: THIS FACILITY HAS BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT EMI&NM 49"5. <br /> LE"DETEQ=,(ELPJ MUST BE PERFORMED. PERIODIC ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED.(23 CCR 2644.1 <br /> SECONDARY CONTAINMENT COMPONENTS ARE TESTED EVERY 36 MONTHS. 490-66 <br /> A3.SPILL BUCKETS ARE TESTED ANNUALLY. 490-67 <br /> VIII.RECORDKEEPING <br /> The following monitoring/maintenance records are kept for this facility: <br /> RAlarm logs 49068a 0 Visual Inspection Records 490-69b Q Tank integrity testing results 49o-6ac <br /> SIR testing results(and supporting documentation records). 490-68d LJ Tank gauging results(and supporting documentation records). 49o-6se <br /> ATG Testing results(and supporting documentation records).49o-6sf [3 Corrosion Protection 60-day logs 4go-6sg <br /> P'Equipment maintenance and calibration records. 490-68h <br /> IX 11LAINING <br /> IN Personnel with UST monitoring responsibilities are familiar with all of the following documents relevant to their job duties. 490-69a <br /> REFERENCE DOCUMENTS MAINTAINED AT FACILITY(Check all that apply) <br /> THIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required)4W.69b <br /> OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required)49o-69c <br /> CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS 49o-69d <br /> CALIFORNIA UNDERGROUND STORAGE TANK LAW 49"% <br /> STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br /> STATISTICAL INVENTORY RECONCILIATION"490-69f <br /> [3 SWRCB PUBLICATION:"UNDERSTANDING AUTOMATIC TANK GAUGING SYSTEMS"49o-69g <br /> 0 OTHER(Specify):m69h,m6% <br /> aThis facility has a"Designated UST Operator"who has passed the California UST System Operator Exam administered by the International Code Council(ICC). <br /> The-Designated UST Operator-will train facility employees in the proper operation and maintenance of the UST systems annually,and within 30 days of hire.This <br /> training will include,but is not limited to,the following: <br /> • Operation of the UST systems in a manner consistent with the facility's best management practices <br /> • The facility employee's role with regard to the monitoring equipment as specified in this UST Monitoring Plan <br /> • The facility employee's role with regard to spills and overfills as specified in the UST Response Plan <br /> • Names of contact person(s)for emergencies and monitoring alarms.49D-7o <br /> X COMIMIENTSIADDITIONAL INFORMATION <br /> Provide additional comments here or indicate how many pages with additional information on specific monitoring procedures are attached to this plan.49D-71 <br /> A e- <br /> P06 <br /> 0/2( A— <br /> M.PERSONNEL RESPONSIBILITIES <br /> The UST ;M%r�)s responsible for ensuring that:1)the daily/routine UST monitoring activities and maintenance of UST leak detection equipment covered by <br /> conditions <br /> 0� <br /> d <br /> thisplan(=curs,42q7a ditions that indicate a possible release are investigated,and 3)all monitoring records are maintained properly. <br /> The following person(s)are responsible for performing the monitoring and equipment maintenance: <br /> NAME 4go-72 TITLE 490-73 <br /> NAME 49o-74 TITLE 490-75 <br /> The Designated Operator shall perform a monthly visual inspection of the facility,provide a report to the owner/operator,and inform the ownedoperator of any <br /> conditions that need follow-up action. <br /> XII.OWNE PER <br /> ATO <br /> CERTIFICLT4PN:I certify that the information Mvided herein is true anaccurateto the best of my knowledge. <br /> APPLICANT Sq*ATURE 490-76 DATE: 490-77 <br /> -Ix <br /> REIRES 0 3.AVAgfixd Ranolling of <br /> 1 <br /> APPLICADF NAME(print): 490-78 APPLICANT TITLE: 4907 <br /> 9 <br /> UPCF UST-D(12/2007)3/4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.