My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
3032
>
2300 - Underground Storage Tank Program
>
PR0231758
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2023 2:52:05 PM
Creation date
6/3/2020 9:52:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231758
PE
2361
FACILITY_ID
FA0002127
FACILITY_NAME
WESTERN FOOD & FUEL
STREET_NUMBER
3032
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3032 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231758_3032 E WATERLOO_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
532
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
File MH29667 Page TI -3 of 2 Issued: "'00" t908 <br />SIMULATED USE RESISTANCE TO FLUIDS TEST (FIBERGLASS REINFORCED PLASTIC SUMP <br />MATERIALS): <br />METHOD <br />one sample assembly as described in Item B was placed in a container <br />filled with each of the fluids Listed below such that the fittings inside the <br />container were completely covered with the fluids. The samples and tluidr, <br />were maintained at a temperature of 100°F throughout the exposure. Following <br />30 days in this condition, the container* were subjected to an internal <br />pressure of 4.5 psig (based on a maximum sump depth of 10.3 ft.) for a 1,,oixod <br />of at least 5 min. while the samples were examined for evidence of leakage, <br />100% Methanol <br />50% Methanol/50% ASTM Reference Fuel C <br />15% Ethanol/85% ASTM Reference Fuel C <br />10% Ethanol/909 ASTM Reference Fuel C <br />15% MTBE/85% ASTM Reference Fuel C <br />RESULTS <br />There was no evidence of leakage <br />SIMULATED USE RESISTANCE TO FLUIDS TEST (FIBERGLASS REINFORCED PLASTIC SUMP <br />MATERIALS): <br />METHOD <br />One sample assembly as described in Item C was placed in a container <br />filled with each of the fluids Listed below such that the fittings inside the <br />container were completely covered with the fluids. The samples and fluido <br />were maintained at a temperature of 100'F throughout the exposure. Following <br />30 days in this condition, the containers were subjected to an internal <br />pressure of 4.5 prig (based on a maximum sump depth of 10.3 ft.) for a period <br />, of <br />at least 5 min. while the samples were examined for evidence of leakage. <br />100% Methanol <br />50% Methanol/50% ASTM Reference Fuel C <br />100% Ethanol <br />Sot Ethanol/SOW ASTM Reference Fuel C <br />15% Ethanol/859 ASTM Reference Fuel C <br />10% Ethanol/90% ASTM Reference Fuel C <br />15% MTBE/85% ASTM Reference Fuel C <br />RESULTS <br />There was no evidence of leakage <br />UL Listing Report 4 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.