My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
3032
>
2300 - Underground Storage Tank Program
>
PR0231758
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2023 2:52:05 PM
Creation date
6/3/2020 9:52:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231758
PE
2361
FACILITY_ID
FA0002127
FACILITY_NAME
WESTERN FOOD & FUEL
STREET_NUMBER
3032
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3032 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231758_3032 E WATERLOO_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
532
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AM "NDEEnvironmental Health Department <br /> SQ�,3JOQQUIN +Zli�rl+a� zg <br /> ---C O U N T Y----- <br /> €l Under a itid Storage T k`Prograrn t ' e00mil ReporE <br /> _ . <br /> Facility Name: Facility Address: Date: <br /> WESTERN FOOD&FUEL 3032 E WATERLOO RD, STOCKTON December 11, 2018 <br /> tSSysteMObsenfatrons , <br /> 314 HSC 25290.1,25290.2, Failed to have secondary containment or secondary containment not tight ❑V ❑R ❑COS <br /> 25291 <br /> 315 HSC 25291(a) Water in secondary containment not removed,analyzed,and properly disposed of(pre-Jul 2003) ❑V ❑R ❑COS <br /> 316 HSC 25290.1(c3), Secondary containment not constructed to prevent water intrusion(after Jul 2003) ❑V ❑R ❑COS <br /> 25290.2(c3) <br /> 317 CCR 2636,2643(c)(1), Line leak detector(LLD)not installed ❑V ❑R ❑COS <br /> 2666(f) <br /> Lea <br /> 318 CCR 2636(f)(2) k detector failed to detect a 3.0 gallons per hour leak at 10 pounds per square inch ■V ■R ■COS <br /> 319 CCR 2635,2637.1, No spill bucket,failed to contain 5 gallons,no means to keep it empty,or failed to be tested ❑V ❑R ❑COS <br /> 2665,2712 <br /> 320 CCR 2635,2637.2, Failure to comply with the installation,inspection,or record keeping of the overfill prevention ■V ❑R ■COS <br /> 2665,2712 <br /> 321 CCR 2635(b)(2) Overfill prevention was overridden ❑V ❑R ❑COS <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status ❑V ❑R ❑COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status ❑V ❑R ❑COS <br /> 324 CCR 2717.1(g) Tampered with red tag ❑V ❑R ❑COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST ❑V ❑R ❑COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms ❑V ❑R ❑COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored ❑V ❑R ❑COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements ❑V ❑R ❑COS <br /> 329 HSC 25298 Failed to comply with all permanent closure requirements ❑V ❑R ❑COS <br /> 330 CCR 2636(f),2666(c), No LLD on the emergency generator that restricts or shuts off the flow or triggers an alarm ❑V ❑R ❑COS <br /> 2666(f) <br /> 331 CCR 2630(d),2641(a) Liquid does not flow into the sump in the event of a leak(i.e.,failure to remove test boot). ❑V ❑R ❑COS <br /> 332 CCR 2631(b&d), Primary and/or secondary containment not constructed in accordance with the established standards ❑V ❑R ❑COS <br /> 2666(b&e) <br /> 333 CCR 2635,2636(b), Failure to comply with the cathodic protection system requirements ❑V ❑R ❑COS <br /> 2662,2712 <br /> 334 CCR 2666(b)(2) Single-walled pipe not upgraded to double-walled interstitially monitored pipe during repair ❑V ❑R ❑COS <br /> 335 CCR 2630,2632,2643, Equipment or methods used to monitor the UST system are not certified by an independent third-party ❑V ❑R ❑COS <br /> 2644.1 <br /> Sin le-Walled -Rlessarized Pi ut <br /> 9 <br /> 401 CCR 2636(a)(3), Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 2641(b) <br /> 402 CCR 2643(d) No monitoring or record maintenance for single-walled conventional suction systems(pre-Jan 1984). ❑V ❑R ❑COS <br /> 403 CCR 2643(d),2661(f) Failure to conduct 0.1 gph test for single-walled conventional suction systems(pre-Jan 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e),2661(f) Biennial 0.1 gph line integrity test for single-walled gravity piping not performed(pre-Jan 1984) ❑V ❑R ❑COS <br /> her VoEattons <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY'OF MOLA`F[�NS <br /> NQ <br /> c. <br /> (CLASS I,CLASS 11 or'MINOR Natke to Comply) <br /> FA0002127 PR0231758 SCO01 12/11/2018 <br /> EHD 23-01 Rev.09/28/2018 Page 3 of 8 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.